Enviro C-10914 owner manual Are Permitted to Reach the Outside Vent Termination

Models: C-10914

1 46
Download 46 pages 31.26 Kb
Page 14
Image 14

Initial Installation

QUALIFIED INSTALLERS ONLY

This fireplace have been tested and certified for use with SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES. SELKIRK DIRECT-TEMP SYSTEM SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “METALBESTOS MDV VENT SYSTEM” kits are available for horizontal venting. When using Simpson Duravent, it is recommended that, before installation, a bead of RTV High Temperature Silicone should be applied to each outer vent joint, and Mil-Pac to each inner joint. When planning an installation, it will be necessary to select the proper length of vent pipe for the particular requirements.

A MINIMUM VERTICAL LENGTH OF 24” (61 cm) TO THE FIRST 90° ELBOW IS REQUIRED. WITH THIS MINIMUM VERTICAL RISE, HORIZONTAL RUNS OF FROM 1 FT (30.5 cm) to 3 FT (91.5 cm)

ARE PERMITTED TO REACH THE OUTSIDE VENT TERMINATION.

BEFORE BEGINNING THE INSTALLATION TAKE CARE TO ENSURE AN APPROPRIATE OUTSIDE LOCATION FOR THE VENT TERMINATION CAN BE ACCOMMODATED. FOLLOW THE VENT LENGTH DIAGRAM

PRECISELY.

VENTING TERMINALS CANNOT BE RECESSED INTO A WALL OR SIDING.

If extra elbows are being used, overall allowable length will be reduced by 3 ft (91.5 cm) per additional elbow.

WARNING: Do not mix parts from different vent manufacturers’s systems.

EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct Vent GS starting collar in conjunction with Secure Vent, Direct-Temp, and Ameri Vent Direct venting systems. Use of these systems with the Direct Vent GS starting collar is deemed acceptable and does not affect the Intertek WH listing of the appliance.

VENT CONFIGURATIONS AND RESTRICTOR SETTINGS:

Figures 12 shows the range of venting options, it shows possible vent configurations if the unit is top vented, for vertical and horizontal terminations, any layout that remains within the shaded area is acceptable. Having the fewest number of elbows is ideal, as they tend to disrupt air movement. Using 45˚ elbows is preferable to using 90˚ elbows. Also, a shorter vent system will perform better than a longer one.

The ENVIRO WESTPORT has been designed with a built in restrictor plate. The restrictor is designed to enhance flame appearance when installing this unit with vertical chimneys as well as installations with longer horizontal vent applications. It does this by controlling the amount of air moving through the vent pipe.

Figure 12 shows the vent restrictor position required,

 

 

relative to the length of vent pipe. Longer vertical

 

 

vent lengths necessitate greater restriction; position

 

 

1 is open and position 5 is maximum restriction (refer

���� ������� �����

to Figure 11). To avoid injury, it is best to make this

������ ���������� �����

adjustment when the fireplace is cool or use welder’s

5

4 32

 

 

1

gloves or oven mitts.

 

 

To access vent restrictor remove the valve cover plate

���� ������� �����

from the right rear corner of the unit by undoing the

���� ���������� �����

5

4 32

two fastening screws.

 

 

1

Loosen the 1⁄4” hex head bolt and adjust to the correct

 

 

setting.

Figure 11: Restrictor plate settings.

 

 

 

14

Page 14
Image 14
Enviro C-10914 owner manual Are Permitted to Reach the Outside Vent Termination

C-10914 specifications

Enviro C-10914 is a cutting-edge eco-friendly product designed to meet the demands of modern environmental sustainability. With a mission to combat pollution and reduce waste, Enviro C-10914 combines advanced technologies and innovative features to create a robust solution for various applications ranging from industrial processes to home usage.

One of the standout features of Enviro C-10914 is its bio-based composition. Made primarily from renewable resources, this product significantly lowers the carbon footprint compared to traditional counterparts. By utilizing biodegradable materials, it ensures that its lifecycle is more sustainable, addressing the pressing issue of plastic waste in the environment.

Incorporating nanotechnology, Enviro C-10914 enhances its performance through improved durability and resilience. This technology not only increases the longevity of the product but also reduces the need for frequent replacements, promoting a more sustainable consumption model. The nanoscale modifications result in superior resistance to chemicals, UV light, and extreme weather conditions, making it suitable for a variety of applications.

Another key characteristic of Enviro C-10914 is its versatility. It is designed for use in diverse sectors, including agriculture, construction, and consumer goods. In the agricultural sector, for instance, it can be utilized in soil amendments, promoting better crop yield while being safe for both plants and animals. In construction, it serves as an eco-friendly alternative for insulation and waterproofing materials.

The product also features an innovative packaging solution that is user-friendly and minimizes material waste. The design allows for easy handling and application, ensuring that users can maximize its benefits without unnecessary burden.

Additionally, Enviro C-10914 is backed by rigorous testing and certifications that validate its environmental claims. Third-party evaluations confirm its biodegradability and overall effectiveness, providing consumers with confidence in their choices.

In summary, Enviro C-10914 exemplifies the future of sustainable products. With its bio-based materials, nanotechnology enhancements, and versatile applications, it stands at the forefront of eco-innovation, addressing the challenges of pollution and resource depletion in an effective, user-friendly manner. This makes it an essential choice for individuals and businesses alike who are committed to making environmentally responsible decisions.