Operating Instructions
AUTOMATIC SAFETY FEATURES OF YOUR PELLET STOVE:
Your pellet Stove has the following safety features:
A. The stove will shut off when the fire goes out and the exhaust temperature drops below 120°F (49°C).
B. The stove has a high temperature safety switch. If the temperature on the hopper reaches 200°F (93°C), the auger will automatically stop and the stove will shut down when the exhaust temperature cools. If this happens, call your local dealer to reset the 200°F (93°C) high limit switch. ALSO FIND
THE REASONS WHY THE UNIT OVERHEATED.
C. If the power goes out, the unit will stop running. When the power comes back on, the stove will not restart unless the exhaust temperature is still above 120°F (49°C) or the unit is in the ON/OFF thermostat mode.
CONTROL BOARD FUNCTIONS:
1.AUGER TRIM: Used to change feed rates on LOW ONLY for poorer quality fuels. Push the Auger Trim button until the number 1 and 5 lights appear on the Heat Level Indicator. This will increase
the feed rate to 2.5 seconds ON time Auger pulse. This is done only on LOW to allow the burning of
|
|
|
| poor quality fuels. Push the button until the number 1 | ||||
|
|
|
| and 4 lights appear, this will reduce the Auger On time | ||||
|
|
|
| to 1.5 second. This setting is for | ||||
|
| | Push the button until just the number 1 light is on, this | |||||
|
|
|
|
|
| |||
|
|
| � | is for a 2 second ON time (standard setting). Refer to | ||||
|
|
|
| Figure 3. |
|
|
| |
|
|
|
| 2. CONVECTION BLOWER CONTROL: Used to turn | ||||
� |
|
| � | the convection blower ON/OFF. Leave the convection | ||||
|
| |
| blower ON for peak efficiency. |
| |||
|
|
| � | 3. AUGER PULSE LIGHT: This light will flash in | ||||
|
|
|
| |||||
|
|
| � | conjunction with the auger. |
| |||
|
| | 4. MANUAL AUGER FEED: If the unit runs out of fuel, | |||||
|
|
| � | this button can be used to “prime the auger system”. | ||||
|
| | ||||||
|
| This button will turn off after 60 seconds and then | ||||||
� |
|
| � | |||||
|
| must be released and pressed again. |
| |||||
|
|
|
| |||||
| |
|
|
| ||||
|
|
|
|
|
|
| ||
|
|
|
| 5. SYSTEM LIGHT: Responsible for signaling the state | ||||
|
|
|
| of the control board. When the light is flashing during | ||||
|
|
|
| |||||
|
|
|
| When the light is solid, the Heat Level Setting can be | ||||
Figure 2: Circuit Board Control Panel Decal | altered. |
|
|
| ||||
6. ON/OFF BUTTON: Used to turn | ||||||||
|
|
|
| |||||
| Auger Trim |
| Auger Trim | Auger Trim | the unit ON and OFF. |
| ||
|
|
| 5 | 7. | HEAT | OUTPUT | INDICATOR: | |
|
|
|
| Shows | the present | heat output | ||
4 |
|
| 2 Seconds |
| ||||
1.5 Seconds |
| 2.5 Seconds | setting. |
|
| |||
|
| "ON" |
|
| ||||
| "ON" | Factory Setting | "ON" |
|
|
| ||
|
| 8. HEAT LEVEL ADJUSTMENT: | ||||||
|
|
|
| |||||
1 |
| 1 | 1 |
| When pressed, will change the | |||
| Figure 3: Auger trim | and heat level indicator. | heat setting of the unit from low to | |||||
| high in five (5) steps. |
|
7