Operating Instructions

OPERATING YOUR PELLET STOVE:

PRE-BURN INSTRUCTIONS: The burn pot liner holes must be clear and the liner installed properly against the ignitor tube for proper operation. Check the hopper for enough pellets to start the unit.

DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN.

MANUAL MODE:

To START: Press the ON / OFF button. The stove will turn on. The system light will flash. The Auger Light will flash with each pulse of the auger (the Auger Feed Rate is pre-programmed during start-up). The Heat Level Indicator will show the Heat Level that the stove will run at after start-up.

If this is the first time the unit has been started or the unit has run out of fuel, the auger will need to be primed. Press the Manual Auger Feed button until fuel starts to drop into the Burn Pot Liner (see

“OPERATING INSTRUCTIONS; STOVE CONTROLS”).

To OPERATE: When a fire has been established, the System Light will turn solid (after approximately 10

-15 minutes) and the Auger Light will continue to flash to the corresponding Heat Level setting. The Heat Level button can now be pressed at this time to change the desired Heat Level Output setting.

The convection blower (room air blower) will turn on. The speed of this blower is controlled by the setting of the heat level output indicator. The convection blower can be turned OFF by depressing the convection blower control button. For the best efficiency and to prevent cycling, the convection blower should be left on at all times.

When operating on LOW HEAT LEVEL, the feed rate can be adjusted, using the auger trim, for different quality fuels. These settings can be used if the fire keeps going out on low (poor quality fuel). Or if the

low setting is too hot for the room (see “OPERATING INSTRUCTIONS; CONTROL BOARD FUNCTIONS”).

THERMOSTAT / SWITCH MODE:

INITIAL START-UP: See above

OPERATION - HI / LOW mode: When the thermostat contacts are closed the stove settings are adjustable as per Manual Mode (see above). When the thermostat contacts open, the circuit board will take control of the settings. The stove will drop down to a low burn until the thermostat contacts close

again. This low burn setting can be adjusted for different fuel qualities (see “OPERATING INSTRUCTIONS;

STOVE CONTROLS - CIRCUIT BOARD”). The stove will come back to the previous HEAT LEVEL setting when the thermostat contacts close again.

OPERATION – ON / OFF mode: When the thermostat contacts close, the unit will light automatically. Once up to temperature, the stove operates the same as in manual mode (see above). When the thermostat contacts open, the unit automatically begins its shutdown routine. The stove will re-light when the thermostat contacts close again.

TURNING YOUR PELLET STOVE OFF:

MANUAL and HI / LOW mode: To turn the unit OFF, simply press the ON / OFF button. This will stop the feed of pellets. The blowers will continue to operate and cool the stove down. When cool enough, the stove will turn off.

ON / OFF mode: To turn the unit OFF, turn the thermostat down or off.

DO NOT unplug unit while Combustion fan is operating.

This may lead to smoke escaping from the stove.

8

Page 8
Image 8
Enviro C-10984 owner manual Thermostat / Switch Mode, Initial START-UP See above

C-10984 specifications

Enviro C-10984 is a cutting-edge environmental technology designed to address a myriad of ecological concerns while promoting sustainability. Launched as a part of an initiative to enhance waste management practices, C-10984 integrates state-of-the-art features and technologies to maximize efficiency and minimize environmental impact.

At the core of Enviro C-10984 is its advanced waste processing system. This system utilizes a combination of mechanical, biological, and thermal methods to reduce waste volume and convert it into reusable resources. The waste-to-energy technology embedded within the C-10984 allows for the transformation of organic waste into biogas, which can then be harnessed for energy generation, significantly decreasing reliance on fossil fuels.

One of the standout characteristics of Enviro C-10984 is its commitment to resource recovery. The system is equipped with a sophisticated sorting mechanism that effectively categorizes waste into recyclable, compostable, and non-recyclable materials. This capability not only streamlines the waste management process but also increases the efficiency of recycling programs, subsequently reducing landfill accumulation.

Another innovative feature of the C-10984 is its real-time monitoring system. Utilizing IoT technology, the device can track waste volume, energy production, and resource recovery metrics. This data-driven approach allows for improved decision-making, enabling municipalities and organizations to optimize their waste management strategies.

The design of Enviro C-10984 emphasizes ease of use and adaptability. The modular architecture enables it to be tailored to different scales, from small communities to large urban centers, ensuring that diverse needs are met. In addition, the system operates quietly and efficiently, adhering to strict regulatory standards while minimizing disruption to surrounding areas.

Lastly, Enviro C-10984 prioritizes user engagement through a dedicated mobile application. This app allows users to monitor their waste production, access educational resources, and receive customized recommendations for reducing waste, thereby fostering a culture of sustainability within users’ communities.

In summary, Enviro C-10984 represents a significant advancement in environmental technology. With its innovative features, commitment to resource recovery, real-time monitoring, and user-friendly design, it stands as a model for future waste management solutions that prioritize eco-friendliness and efficiency. Through such technologies, we can better address environmental challenges and contribute to a more sustainable future.