Refer to Figures 11 and 12.

Installation

CLEARANCES TO COMBUSTIBLES - BUILT-IN HEATER:

Refer to Figures 11 and 12.

 

 

Side wall to unit

- 8 inches

(20.3 cm)

Mantel projection

- 10 inches

(25.4 cm)

Mantel to top of unit

- 8 inches

(20.3 cm)

Top facing to unit

- 8 inches

(20.3 cm)

Side facing to unit

- 6 inches

(15.2 cm)

Floor protection

- 6 inches

(15.2 cm)

(on either side and to the front must be protected by

non-combustible material)

 

 

Sides and rear walls to standoffs:

- 0 inches

(0 cm)

Recess depth:

- 11 inches

(30 cm)

 

33"

 

(84 cm)

 

12"

 

(30.5 cm)

 

30"

 

(76 cm)

 

6"

 

(15 cm)

6"

Floor Protection

(15 cm)

Figure 12: EF3 Built-In Heater recommended

framing.

PEDESTAL INSTALLATION:

The all models comes with a pedestal that has to be attached prior to installation:

• Remove the unit from the box

• Remove the freestanding pedestal from the box. Remove the FPI or BIH pedestal from the hopper

Figure 14: Fireplace Insert Pedestal.

������� ���� ���

������ �����

Figure 13: Freestanding Pedestal.

• Place the unit on its back on the pallet.

• Back the four (4) 5/16” hex head screws in the base off three (3) to four (4) full turns.

• Align the keyholes in the pedestal with the screws, lock into place.

Secure the two (2) pieces by tightening the four (4) screws from the inside of the pedestal for the freestanding

or from the outside of the pedestal for the FPI or BIH.

Figure 15: Built-In Heater Pedestal.