Enviro EG40-070 owner manual Initial Installation, Qualified Installers Only

Models: EG40-070

1 36
Download 36 pages 19.42 Kb
Page 22
Image 22
2. Set the gas appliance in the desired location.
Roofing nails
Figure 30: Vertical Vent Termination Installation.

Initial Installation

QUALIFIED INSTALLERS ONLY

VERTICAL INSTALLATION:

1.Check the instructions for required clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, or other nearby combustible surfaces. Do not pack air spaces with insulation.

2. Set the gas appliance in the desired location.

 

Drop a plumb bob down from the ceiling to the

 

position of the appliance flue exit, and mark

 

the location where the vent will penetrate the

 

ceiling. Drill a small hole at this point. Next, drop

 

a plumb bob from the roof to the hole previously

 

drilled in the ceiling, mark the spot where the

 

vent will penetrate the roof. Determine if ceiling

 

joists, roof rafters, or other framing will obstruct

 

the venting system. You may wish to relocate

 

the appliance, or to offset, to avoid cutting load

 

bearing members.

 

3. To install the Round Support Box/Wall Thimble

 

in a flat ceiling, cut a 10 inch (25.4 cm) square

 

hole in the ceiling, centered in the hole drilled in

 

Step 2. Frame the hole as shown in Figure 29.

Figure 29: Wall Framing for 10” (25.4 cm) x 10” (25.4

 

4. Assemble the desired lengths of black pipe and

cm) Hole for Vertical Installation.

elbows necessary to reach from the appliance

 

adapter up through the Round Support Box. Insure that all pipe and elbow connections are in their fully twist-locked position.

5.Cut hole in the roof centered on the small hole placed in the roof from Step 2. The hole should be of sufficient size to meet minimum requirements for Clearance to Combustibles, as specified. Continue to assemble lengths of pipe and elbows necessary to reach from the ceiling support box up through

the roof line. Galvanized pipe

 

Vertical

and elbows

may be

utilized in

 

the attic, as well as above the

 

Termination

 

 

roof line. The galvanized finish

Elbow Strap

Storm Collar

is desirable above the roof line,

 

 

due to the

higher

corrosion

 

Flashing

resistance.

 

 

 

 

 

 

 

6. Once the pipe sections have been joined, and run up through the hole in the roof, slip an elbow strap over the exposed sections, bend the support straps outwards, and push the elbow strap down to the roof level, as shown in Figure 30. Tighten the clamp around the pipe section. Use a level to make sure the pipe is truly vertical. With roofing nails, secure the