Installation

THROUGH WALL WITH VERTICAL RISE AND HORIZONTAL TERMINATION INSTALLATION- RECOMMENDED:

A 45° elbow with a rodent screen may be used in place of the termination cap (or stainless steel termination hood).

���� �������

����������� ���

�������� ���� �������

�������� �������

�� ���� ����

�����������

��

Figure 15: Venting horizontally with rise.

THROUGH CONCRETE WALL WITH VERTICAL RISE INSTALLATIONS:

A 45° elbow with a rodent screen may be used in place of the termination cap (or stainless steel termination hood).

Installation to use if there is a concrete or retaining wall in line with exhaust vent on pellet stove.

The termination must be 12 inches (30 cm) from the outside wall and 12 inches (30 cm) above the ground.

Horizontal frame

 

Termination cap

for thimble

 

 

 

Wall thimble

90o elbow

Wall framing

Vertical section of vent pipe

Concrete Wall

EF 5

Clean out tee

Figure 16: Venting with concrete wall behind unit .

19

Page 19
Image 19
Enviro C-10825, Evolution owner manual Venting horizontally with rise