AUTO/OFF
HIGH/LOW MANUAL
Figure 5: Thermostat Switch in
ON/OFF position.
MODE
AUTO/OFF
HIGH/LOW
MANUAL
Figure 3: Thermostat Switch in
MANUAL position.

Operating Instructions

MANUAL MODE:

All control of circuit board function is adjusted at the circuit board.

To START: Press the ON / OFF button. The stove will turn on. The system light will flash. The Auger Light will flash with each pulse of the auger (the Auger Feed Rate is pre-programmed during start-up). The Heat Level Indicator will show the Heat Level that the stove will run at after start-up and can be adjusted but the change will not take affect until the start -up has finished.

If this is the first time the unit has been started or the unit has run out

of fuel, the auger will need to be primed. This can be done by restarting the unit five (5) minutes into its start-up or by putting a small hand full of pellets into the burnpot.

To OPERATE: When a fire has been established, the System Light will turn solid (after approximately 10 - 15 minutes) and the Auger Light will continue to flash to the corresponding Heat Level setting.

The convection blower (room air blower) will turn on. The speed of this blower is controlled by the setting of the heat level output indicator. The convection blower can be turned OFF by depressing the convection blower control button. For the best efficiency the convection blower should be left on at all times.

HIGH/LOW MODE: (Requires a thermostat)

 

 

 

MODE

 

 

 

 

INITIAL START-UP: See manual mode above.

 

 

 

AUTO/OFF

 

 

 

OPERATION: When the thermostat calls for heat (contacts are closed)

 

 

 

 

 

 

HIGH/LOW

 

 

 

the stove settings are adjustable as per Manual Mode. When the

 

 

 

 

 

 

MANUAL

thermostat contacts open, the HEAT LEVEL and Fans will drop down to

 

 

 

 

the LOW setting until the thermostat contacts close again. *The LOW

 

 

 

 

heat setting can be adjusted for different fuel qualities (see “OPERATING

Figure 4: Thermostat Switch in

INSTRUCTIONS - CONTROL BOARD FUNCTIONS”). The stove will come back to

 

HIGH/LOW position.

the previous HEAT LEVEL setting when the thermostat contacts close

 

 

 

 

 

 

 

MODE

again.

 

 

 

 

 

 

 

 

 

 

 

 

AUTO/OFF MODE: (Requires a thermostat)

INITIAL START-UP: See manual mode above.

OPERATION: When the thermostat contacts close, the unit will light automatically. Once up to temperature, the stove operates the same as in MANUAL. When the thermostat contacts open, the stove’s HEAT

LEVEL and Fans will drop down to the LOW setting for 30 minutes. If

the thermostat contacts close within the 30 minutes, the HEAT LEVEL will return to the previous MANUAL setting. If the thermostat contacts remain open the stove automatically begins its shutdown routine. The ON / OFF button can be presses at any time the the stove will immediately shut down. The stove will re- light when the thermostat contacts close again.

TURNING YOUR PELLET STOVE OFF:

MANUAL and HI / LOW mode: To turn the unit OFF, simply press the ON / OFF button. This will stop the feed of pellets. The blowers will continue to operate and cool the stove down. When cool enough, the stove will turn off.

AUTO / OFF mode: To turn the unit OFF, turn the thermostat down or off. NOTE: The unit will run on low for three (3) minutes before it turns off.

DO NOT unplug unit while Combustion fan is operating.

This may lead to smoke escaping from the stove.

8

Page 8
Image 8
Enviro Mini A owner manual Manual Mode, Thermostat Switch

Mini A specifications

The Enviro Mini A is a compact and efficient solution designed for a variety of environmental monitoring applications. As the demand for sustainable practices increases, the Enviro Mini A emerges as a key player in facilitating real-time data collection and analysis of environmental parameters.

One of the main features of the Enviro Mini A is its advanced sensor technology. It is equipped with high-precision sensors that can monitor various environmental factors, including air quality, temperature, humidity, and atmospheric pressure. These sensors are designed to provide accurate readings, allowing users to make informed decisions based on reliable data.

The design of the Enviro Mini A is another significant characteristic that sets it apart. Its compact size allows for easy installation in a variety of locations, from urban settings to remote areas. This versatility makes it suitable for deployments in schools, parks, industrial sites, and research facilities. The device can be mounted on poles, walls, or placed on flat surfaces, ensuring flexibility in how it can be utilized.

Connectivity is a critical aspect of the Enviro Mini A's functionality. The device is equipped with Wi-Fi and optional cellular connectivity, enabling seamless data transmission to cloud-based platforms for real-time analysis and monitoring. Users can access the data remotely via a user-friendly interface, allowing for quick responses to any environmental changes or alerts.

The Enviro Mini A also boasts a robust and weather-resistant design, making it capable of withstanding various environmental conditions. This durability ensures longevity and reliability, even in challenging outdoor settings. Furthermore, the device is energy-efficient, often powered by solar energy or a long-lasting battery, which reduces maintenance efforts and operational costs.

Incorporating advanced data analytics capabilities, the Enviro Mini A allows users to track trends over time, identify patterns, and generate reports that can assist in regulatory compliance and environmental assessments. Its integration with machine learning algorithms aids in predictive analytics, offering insights that can drive proactive environmental management strategies.

In summary, the Enviro Mini A is a state-of-the-art environmental monitoring device that combines advanced sensor technology with a robust design and connectivity features. Its versatility and analytical capabilities make it an invaluable tool for anyone looking to monitor and improve environmental conditions effectively.