Operating Instructions

CONTROL BOARD FUNCTIONS:

1.ON/OFF BUTTON: Used to turn the unit ON and OFF manually.

2.FUEL TYPE BUTTON: Used to switch between fuel type modes; Pellet (for all qualities of wood

 

 

PELLET

4

 

 

 

5

 

MULTIFUEL

 

 

 

 

 

 

AUTO/OFF

3

 

 

HIGH/LOW

 

 

MANUAL

 

 

 

 

2

6

HEAT LEVEL

FUEL TYPE

 

 

 

7

 

 

1

 

FEED TRIM

ON/OFF

 

 

 

C-11256

 

Figure 2: Circuit Board Control Panel Decal

pellets) and Multifuel (for all fuels including wood pellets). When set on Multifuel it will run at a reduced High Feed Rate with wood pellets. NOTE: Fuel Type can only be chnaged when the unit is cold.

3.THERMOSTAT SWITCH: Sets the unit’s control mode; AUTO/OFF or HIGH/LOW (when using a Thermostat or Timer) or MANUAL.

4.FUEL TYPE LIGHTS: Shows the present Fuel Type selected; Pellet is green and Multifuel is yellow. The light flashs during start-up and stops flashing when the 49°C (120°F) switch closes.

5.HEAT OUTPUT INDICATOR: Shows the present Heat Level output setting and the Feed Trim while it is being adjusted.

6.HEAT LEVEL ADJUSTMENT BUTTONS: When pressed, will change the heat setting of the unit from low to high. Arrow up button to increase heat and arrow down to decrease heat.

7.FEED TRIM BUTTON: Used in conjunction with the Heat Level adjustment buttons to adjust the Feed Trim. It can be increased by two (2) feed settings or it can be decreased by two (2) feed settings. The Feed Trim can only be adjusted one setting at a time. This button can also be used to “prime the auger system”.

AUTOMATIC SAFETY FEATURES OF YOUR PELLET STOVE:

A.EXHAUST TEMPERATURE SWITCH: The stove will shut off when the fire goes out and the exhaust temperature drops below 49°C (120°F).

B.HIGH LIMIT SAFETY SWITCH: If the temperature on the hopper reaches 93°C (200°F), the auger will automatically stop, the stove will shut down, and it will display a #4 flash code. If this happens, call your local dealer to reset the 93°C (200°F) high limit switch. ALSO FIND THE REASONS WHY THE

UNIT OVERHEATED.

C.VACUUM SWITCH: If the combustion fan fails or the exhaust vent becomes blocked this switch will stop the auger feed motor and the fire will go out.

OPERATING YOUR PELLET STOVE:

DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH BOX OPEN. Keep hopper lid closed except during re-fuelling.

CAUTION: When operating during adverse weather, such as high winds or freezing rain, if the unit exhibits dramatic changes in combustion stop using the unit immediately. Watch for blocked exhaust outlet.

7

Page 7
Image 7
Enviro C-11256, Omega, C-11407, 50-1675 owner manual Unit Overheated, Circuit Board Control Panel Decal

50-1675, C-11256, Omega, C-11407 specifications

Enviro C-11407, Omega, and C-11256, 50-1675 are cutting-edge technologies designed to address various environmental challenges through innovative engineering and advanced features. These systems have been developed for a wide range of applications, including waste management, air quality improvement, and resource conservation.

Enviro C-11407, known for its robust design, focuses on waste reduction and recycling processes. This system incorporates a modular architecture that allows for easy integration into existing waste management facilities. With its high-efficiency sorting capability, the C-11407 employs advanced sensors and machine learning algorithms to identify recyclable materials. The system can significantly increase the recovery rates of recyclable materials while reducing operational costs.

Omega technology, on the other hand, is geared towards air quality enhancement. This system utilizes sophisticated filtration and purification methods to remove pollutants from the atmosphere. The Omega unit employs a multi-stage filtration process, which includes HEPA filters, activated carbon, and photocatalytic oxidation, ensuring the highest level of air purification. Its smart monitoring system provides real-time data on air quality, allowing for proactive measures to be taken against pollution spikes, thereby improving public health and environmental conditions.

C-11256 is an advanced energy management system aiming to improve energy efficiency and reduce carbon footprints. This technology integrates renewable energy sources such as solar and wind with smart grid capabilities. The C-11256 utilizes energy storage systems that can store excess energy for use during peak demand times. Its predictive analytics feature allows users to optimize energy consumption, contributing to substantial cost savings and a decrease in greenhouse gas emissions.

The 50-1675 model represents a versatile solution for water treatment applications. This system features advanced membrane filtration technology capable of removing contaminants at the molecular level. With a focus on sustainability, the 50-1675 is designed to minimize water wastage while maximizing contaminant removal efficiency. Its compact design makes it suitable for various settings, including industrial processes, municipal water treatment, and even portable applications for remote areas.

Together, these technologies—Enviro C-11407, Omega, C-11256, and 50-1675—highlight a commitment to innovation in environmental management. By harnessing cutting-edge engineering and advanced analytical tools, they promote sustainability, enhance resource recovery, and improve overall quality of life for communities worldwide.