1.2.5 Environmental Conditions
Table 1-4. Environmental Conditions
Description Operating Storage
Temperature
10-35 ‘c (50 - 95 ‘I=)(*1) -20- 60
“C
(-4 - 140 ‘F) (*2)
Humidity
20- 80% RH (*1,*3) 5-
85~0
RH (*2,*3)
Resistance to shock
1 G, within 1
msec.
2 G, within 2
msec.
(*2)
Resistance to vibration
0.15 G, 10-55 Hz 0.50 G, 10-55 Hz (*2)
Note:
1 = Operating conditions must be in this range.
*2= When the printer is in the shipping container.
3 = Without condensation.
Humidity
(%RH)
80Y0
55~o
20?/0
.
.
.
.
.
.
.
Print assured range
/
. . . . . . . .
10” C
27°
C 35°C
‘c
(50” F) (80” F) (95” F) (“F)
Figure 1-6. Temperature/ Humidity Range
1.2.6 Electrical Specifications
Table 1-5. Electrical Specifications
Item 120V Version
220- 240V Version
Rated voltage
120V AC
220- 240V AC
Input voltage range
103.5- 132V 198- 264V
Rated frequency range
50- 60 Hz 50- 60 Hz
Input frequency range
49.5- 60.5 Hz 49.5- 60.5 Hz
Rated current
0.5 A 0.3 A
Power consumption
Approx.
13W
Approx.
13W
(self test with 10
cpi
LQ characters) (self test with 10
cpi
LQ characters)
10
MQ,
minimum 10
MQ,
minimum
Insulation resistance
(applying
500VDC
between AC line
(applying 500VDC between AC line
and chassis) and chassis)
10OOVAC
rms
-1 minute or
Dielectric strength
1200VAC
rms
-1 second 1500VAC
rms
-1 minute
(between AC line and chassis) (between AC line and chassis)
Rev. A
1-7