5 Attach the Fan.

Align the direction, insert the fan, and then secure it in place with the two screws.

Point

·Ensure that the lamp has been firmly secured in place. For safety reasons, this projector has been designed so that the power supply is automatically disconnected when the fan is removed. It will not be possible to switch on the power supply unless the lamp and Fan have been properly fitted.

·A replacement Air Filter is packaged with the replacement lamp. Replace the Air Filter at the same time as replacing the lamp.

·Ensure that the lamp illumination time is reset in accordance with the following procedure after the lamp has been replaced with a new one.

Resetting the lamp illumination time

1 Press the [Help] button for five or more consecutive seconds.

The screen for resetting the lamp's illumination time will be displayed after the help menu has been displayed.

 

Power

Help

Menu

 

 

Help

Computer

Video

g

 

 

 

ni

 

 

 

k

 

 

 

c

 

 

 

a

 

 

 

r

 

 

 

T

 

A/V mute

 

 

 

Resize

 

 

 

 

 

Shift

Esc

Sync.

T

r a c k i gn

Sync.

Keystone

Volume

Help

Esc

Menu Help

Comp1 Comp2/BNC

Video

Auto Resize

P in P

Preset

- Volume +

2 Select [Yes]

Press the [Tracking +, -] on the main unit (lower the [Enter] button on the remote control unit) and select [Yes].

Reset Lamp ON Time

Do you reset the Lamp ON Time?

YesNo

:Select :Execute

3 Execution

Press the [ (Enter)] button on the main unit or the [Enter] button on the remote control unit to execute the process.

Replacing the Lamp - 93