8.2.2. Control register (Reg F)Address | Function | bit 7 | bit 6 | bit 5 | bit 4 | bit 3 | bit 2 | bit 1 | bit 0 | |
|
|
|
|
|
|
|
|
|
| |
F | Control Register | ! | ! | UIE | TIE | AIE | ! | STOP | RESET | |
(Default) | (0) | (0) | (− ) | (− ) | (− ) | (0) | (− ) | (− ) | ||
|
∗1) The default value is the value that is read (or is set internally) after powering up from 0 V.
∗2) "o" indicates
∗3) "− " indicates no default value has been defined.
•This register is used to control interrupt event output from the /INT pin and the stop/start status of clock and calendar operations.
1) UIE (Update Interrupt Enable) bitWhen a time update interrupt event is generated (when the UF bit value changes from "0" to "1"), this bit's value specifies if an interrupt signal is generated (/INT status changes from
When a "1" is written to this bit, an interrupt signal is generated (/INT status changes from
When a "0" is written to this bit, no interrupt signal is generated when an interrupt event occurs.
UIE | Data | Function |
| 0 | When a time update interrupt event occurs, an interrupt signal is not |
| generated or is canceled (/INT status changes from low to | |
|
| |
|
|
|
Write/Read |
| When a time update interrupt event occurs, an interrupt signal is generated |
| (/INT status changes from | |
| 1 | |
| ∗ When a time update interrupt event occurs, | |
|
| the value of the control register's UIE bit is "1". This /INT status is automatically cleared (/INT |
|
| status changes from low to |
∗For details, see "8.4. Time Update Interrupt Function".
2)TIE (Timer Interrupt Enable) bitWhen a
When a "1" is written to this bit, an interrupt signal is generated (/INT status changes from
When a "0" is written to this bit, no interrupt signal is generated when an interrupt event occurs.
TIE | Data | Function |
| 0 | When a |
| generated or is canceled (/INT status changes from low to | |
|
| |
|
|
|
Write/Read |
| When a |
| generated (/INT status changes from | |
| 1 | |
| * When a | |
|
| occurs only when the value of the control register's TIE bit is "1". Up to 7.8 ms after the interrupt |
|
| occurs, the /INT status is automatically cleared (/INT status changes from low to |
∗For details, see "8.3.
When an alarm timer interrupt event occurs (when the AF bit value changes from "0" to "1"), this bit's value specifies if an interrupt signal is generated (/INT status changes from
When a "1" is written to this bit, an interrupt signal is generated (/INT status changes from
When a "0" is written to this bit, no interrupt signal is generated when an interrupt event occurs.
AIE | Data | Function |
| 0 | When an alarm interrupt event occurs, an interrupt signal is not generated |
| or is canceled (/INT status changes from low to | |
|
| |
|
|
|
Write/Read |
| When an alarm interrupt event occurs, an interrupt signal is generated |
| (/INT status changes from | |
| 1 | |
| ∗ When an alarm interrupt event has been generated | |
|
| only when the value of the control register's AIE bit is "1". This setting is retained until the AF bit |
|
| value is cleared to zero. (No automatic cancellation) |
∗For details, see "8.5. Alarm Interrupt Function".
[Caution]
(1)The /INT pin is a shared interrupt output pin for three types of interrupts. It outputs the OR'ed result of these interrupt outputs.
When an interrupt has occurred (when the /INT pin is at low level), the UF, TF, read AF flags to determine which flag has a value of "1" (this indicates which type of interrupt event has occurred).
(2)To keep the /INT pin from changing to low level, write "0" to the UIE, TIE, and AIE bits. To check whether an event has occurred without outputting any interrupts via the /INT pin, use software to monitor the value of the UF, TF, and AF interrupt flags.
Page - 7 |