♣Important!
When connecting or disconnecting the power supply from the printer, be sure that the following cautions are observed.
(1)Use a power supply (Limited Power Supply) of DC 24V±10% and more than 2.5A.
(2)Be careful about installing the printer in an area where there is noise.
(3)Take the appropriate measure to protect against electrostatic AC line noise, etc.
6-5. Environmental Requirements
(1) Operating |
|
Temperature | 5°C to 40°C |
Humidity | 10% to 90% RH (without condensation) |
(2) Transport/Storage (except paper) | |
Temperature | |
Humidity | 10% to 90% RH (without condensation) |
6-6. Reliability
(1) | MCBF | 60 million lines (based on an average printing rate of 12.5% with paper |
|
| thickness in the range of from 65µm - 75µm) |
|
| 35 million lines (based on an average printing rate of 12.5% with paper |
|
| thickness in the range of from 76µm - 150µm) |
(2) | Head Life | 100 million pulses, 100Km |
(3) | Cutter Life | 1.0 million cuttings (if the paper thickness is between 65 and 100 µm) |
6-7. Certification
(1)FCC PART15 CLASS A
(2)CE EMCD/LVD
(3)UL/cUL
(4)MIC
24