Equator PAC 12, PAC 8, PAC 10 Troubleshooting, Action, Check code, Diagnosis of malfunction

Models: PAC 8 PAC 12 PAC 10

1 20
Download 20 pages 41.63 Kb
Page 19
Image 19
TROUBLESHOOTING

TROUBLESHOOTING

Before seeking repair or service, please check the following.

Trouble

Check

Action

Air Conditioner does not

Is there power?

It is normal.

operate at all

Is the unit plugged in?

Push the plug into the wall

 

 

socket

 

Did the fuse or circuit breaker

Change the fuse.

 

break off?

Change SET TIME

 

Is SET TIME suitable?

 

 

 

Cooling efficiency is not good

Is air inlet or outlet blocked?

Clear the blockage

 

Is there any other heat source

Move the heat source

 

in room?

Clean the air filter

 

Are air filters very dirty?

 

Is SET TEMP suitable?

Set temperature suitable

 

Is indoor fan speed set at low?

Set suitable fan speed.

Too noise and vibration

It is the inner liquid

it is normal

 

(refrigerant) flowing inside.

 

 

Is unit leveled?

Place it in a horizontal floor

The machine start and stop

Is the voltage of the power

Make sure the power source is

frequently

source normal?

rated at 110-115V/60Hz

 

Is the air exhaust fixed

Try to keep the air exhaust

 

correctly?

horizontal

 

Are you adding air exhaust

Don’t add air exhaust yourself

 

yourself?

and remove it

Call for service when:

The fuse and switch often break.

The power cord superheats or the sleeve of the cord broken.

You detect something abnormal.

Self diagnosis function

Our company provides the end-users with thoughtful services by installing various diagnostic systems to indicate the following irregular performances.

 

Check code

 

Diagnosis of malfunction

 

FAULT E8

 

Overheating protection

 

FAULT E3

 

Faulty coils

 

 

 

 

 

FAULT E2

 

Room temperature faults

 

 

 

 

 

FAULT E4

 

Units faults

 

 

 

 

 

FAULT E5

 

Condensed water in water tank is

 

 

over limited level.

 

 

 

 

 

 

18

Portable Air Conditioner Owner’s Manual

Page 19
Image 19
Equator PAC 12, PAC 8, PAC 10 owner manual Troubleshooting, Action, Check code, Diagnosis of malfunction

FAQ

What should I check if my air conditioner does not operate at all?

First, make sure there is power and that the unit is plugged in. If the fuse or circuit breaker has broken off, change it. Also, ensure the SET TIME is suitable.

How can I improve the cooling efficiency of my air conditioner?

Clear any blockages from the air inlet or outlet, move any heat sources in the room, and clean the air filter.

Why is my air conditioner making too much noise and vibration?

This could be due to the inner liquid refrigerant flowing inside. Also, ensure that the unit is placed on a horizontal floor.