Ericsson TT1222 manual Warnings, Fuse Type and Rating, Power Supply

Models: TT1222

1 20
Download 20 pages 32.89 Kb
Page 10
Image 10
Fuse Type and Rating

2BInstalling the Equipment

2.5Connecting the Receiver to the Power Supply

Warnings!

Do not overload wall outlets and extension cords as this can result in a risk of fire or electric shock.

As no mains switch is fitted to this unit, ensure the local power supply is switched OFF before connecting the supply cord.

The Receiver is not fitted with an on/off switch. Ensure that the socket-outlet is installed near the equipment so that it is easily accessible. Failure to isolate the equipment properly may cause a safety hazard.

Connect the Receiver to the power supply as follows:

Power Supply

Ensure the power supply is isolated and switched off.

Receiver

Ensure the correct fuse type and rating has been fitted to both the equipment and the power cable.

Supply Cord

Connect the lead to the Receiver input connector and then to the power supply. Switch on the power supply.

Table 5

Fuse Type and Rating

Power Supply

Fuse Type and Rating

 

 

100-240 V AC –10% +6% at

5 x 20 mm

50/60 Hz nominal

IEC/EN 60127-2 Sheet 2

 

 

Hollyand 5OF or Littelfuse 617

 

 

F3.15 A 250 V

 

 

Note: The Internal fuse is not user replaceable

 

Refer to the Reference Guide for all power supply, fuse, safety, EMC

 

information and operating conditions.

10 (20)

EN/LZT 790 0002/1 R1A 2011-02-21