Escali E3CB, E6CB, E30CBB, E15CB manual Error Indication and its Information, Solution

Models: E15CB

1 12
Download 12 pages 57.9 Kb
Page 11
Image 11
■Procedures to set up time to automatically turn off the power
Set up the preferable time to turn off the power by using the “+” key or “=” key while the display is showing as picture No. 2. Complete the procedures to set up the time using the “M” key. Not pushing the “M” key does not save this function.
z The scale is automatically turned off when not being used for selected time without inputting a key or changing the weight. z Used in order to prevent unnecessary consumption of the battery.
z Select time to automatically turn off the power as OFF – 5min.- 10min. – 30min. – 60min. – 120min. z Release the time setup by setting up with ‘OFF’.
z Without inputting a key for 5 seconds will automatically set back to the scale mode in the picture No. 2.
z The scale is dispatched with ‘5 minutes automatic turning off the power’ mode. (The scale is automatically turned off when not being used
for 5 minutes.)
W eighing range :40 g ~ 6/15 kg,e = d :2 g / 5 g
(0.1 lb ~ 15/30 lb,e = d :0.005 lb/0.01 lb)
Model : CB-15N
BAT
g/pc
TOTAL lb
UNIT WEIGHT
pcs
Short
Q'ty
Short
Unit Wt.
QUANTITY
kg
ZERO TARE
WEIGHT
W eighing range :40 g ~ 6/15 kg,e = d :2 g / 5 g
(0.1 lb ~ 15/30 lb,e = d :0.005 lb/0.01 lb)
of the scale are zero state and Tare is released as the picture No. 1.
kg
pcs
g/pc

Procedures to set up time to automatically turn off the power

-Push the “C” key for 5 seconds while the weight, quantity, unit weight

-

-

WEIGHT

ZERO

TARE

QUANTITY

Short

Q'ty

Short

Unit Wt.

UNIT WEIGHT

TOTAL lb

BAT

Model : CB-15N

7. Error Indication and its Information

Error

Information

Solution

Error

Information

Solution

Err-01

Memory reading error

A/S

Err-02

Zero range error (Test mode)

A/S

Err-03

Problems in Weighing range (Test mode)

A/S

Err-d0

Exceed maximum weight

Check the platform, A/S

Err-d1

Below minimum weight

Check the platform

Err-d2

Problems in AD converter

A/S

Err-d3

Tare range error: Unstable condition, Exceed

Check the scale

Err-d4

Exceed maximum data range of AD

Check to see if there is anything

 

tare range, Setting up the Tare during “-

 

 

converter

on the platform, A/S

 

(minus)“ weighing

 

 

 

 

Err-d5

Below minimum data range of AD converter

Check the platform, A/S

Err-d6

Weighing range error

A/S

Err-d7

Problems in Zero / Exceed the range

A/S

Err-d8

Not in a stabilized condition

The scale is experiencing

 

 

 

 

 

vibrations or wind currents : Place

 

 

 

 

 

the scale in a stabilized condition

-When the scale stops operating or ON/OFF key does not operate

-Reset the battery or adapter jack. When they do not operate after resetting the battery or adapter jack, claim the after service.

Page 11
Image 11
Escali E3CB Error Indication and its Information, Procedures to set up time to automatically turn off the power, Solution