3
TOOLS AND SUPPLIES YOU WILL NEED
• Pliers
• Screwdrivers
Adjustable Wrenches
Tubing Cutter
5/32 Hex Key Wrench
Electric Drill
Drill Bits
• Hammer
Duct Caulking
#10 Sheet Metal Screws
Wiring Supplies, as Required by Local Electrical Code
•Level
Duct. As Required (a local sheetmetal shop can
supply ducting.)
Equipment Suitable for installing Duct Through House
Wall or Roof
1/4" Water Line
Saddle Valve
ECR-7 Wall Switch (7 position). Use ECR-5 (5 posi-
tion) with existing pump type cooler wiring
Roof Stand Kit (if cooler is roof mounted)
Cooler ECR 3301 - use ECK-30 kit
Cooler ECR 4000 - use ECK-40 kit
Cooler ECR 4500 - use ECK-40 kit
Cooler ECR 5200 - use ECK-50 kit
Cooler ECR 6600/7200 - use ECK-60 kit
RULES FOR YOUR SAFETY
1.

WARNING

TO AVOID FIRE, SHOCK, OR

SERIOUS PERSONAL INJURY

FOLLOWING THESE INSTRUCTIONS.

2. The installation must conform to local codes and
utility standards. Use the National Electric Code if
a local code does not exist.
3. Disconnect the electric power EVERY TIME you
work on your cooler. When your hands are inside
the cooler you risk injury if the cooler is accidentally
turned on from inside the home.
4. If you mount the cooler on your home roof remember
these safety tips:
5. Never install or service a cooler during a storm or
high wind conditions. You could be injured or lose or
damage parts.
6. Never wear shoes with slick soles when you work on
a roof. You may slip when you least expect it.
7. Never drain water onto a roof. Water residue may
cause you to slip or may stain your roof. Use a drain
hose to run the drain water to a rain gutter or to a
drain.
8. To avoid injury never use the cooler without connect-
ing it to a house duct system or without a sturdy fine
mesh guard over the outlet.
DATA
Cabinet Dimensions Air Output Opening Operating
Model (inches) (inches) Lbs. Weight
No. Height Width Depth Height Width (with water)
ECR 3301 251/4251/4391/8133/4133/4140
ECR 4000 293/4293/4353/16 173/4173/4190
ECR 4500 293/4293/4353/16 173/4173/4195
ECR 5200 333/4333/4371/2193/4193/4235
ECR 6600 363/4363/44213/16 193/4193/4285
ECR 7200 363/4363/44213/16 193/4193/4290
ESSICK EVAPORATIVE OUTPUT RATINGS
PAD USAGE (Cubic Feet per Minute)
Model Essick Industry Sizing
No. Pad Number Rating
ECR 3301 EP-30 3300 cfm
ECR 4000 EP-40 4000 cfm
ECR 4500 EP-40 4500 cfm
ECR 5200 EP-50 5200 cfm
ECR 6600 EP-60 6600 cfm
ECR 7200 EP-60 7200 cfm
INSTALLATION