General Safety Instructions

READ BEFORE USING YOUR HUMIDIFIER

DANGER: means if the safety information is not followed someone will be seriously injured or killed.

WARNING: means if the safety information is not followed someone could be seriously injured or killed.

CAUTION: means if the safety information is not followed someone may be injured.

1.To reduce the risk of fire or shock hazard, this humidifier has a polarized plug (one blade is wider than the other.) Plug humidifier directly into a 120V, A.C. electrical outlet. Do not use extension cords. If the plug does not fully fit into the outlet, reverse plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.

2.Keep the electric cord out of traffic areas. To reduce the risk of fire hazard, never put the electric cord under rugs, near heat registers, radiators, stoves or heaters.

3.Always unplug the unit before moving, cleaning or removing the fan assembly section from the humidifier, or whenever it is not in service.

4.Keep the humidifier clean.

5.Do not put foreign objects inside the humidifier.

6.Do not allow unit to be used as a toy. Close attention is necessary when used by or near children.

7.Never use your humidifier while any part is missing or damaged in any manner.

8.To reduce the risk of electrical hazard or damage to humidifier, do not tilt, jolt or tip humidifier while unit is running.

9.To reduce the risk of damage to humidifier, unplug when not in use.

10.To reduce the risk of accidental electrical shock, do not touch the cord or controls with wet hands.

11.To reduce the risk of fire, do not use near an open flame such as a candle or other flame source.

12.Note the warning label shown below.

WARNING: To reduce risk of fire, electric shock, or injury always unplug before servicing or cleaning.

INTRODUCTION

Your Essick Air evaporative humidifier adds invisible moisture to your home by moving dry inlet air through a saturated wick. As air moves through the wick, the water evaporates into the air, leaving behind any white dust, minerals, or dissolved and suspended solids. Because the water is evaporated, there is just clean and invisible moist air.

As the evaporative wick traps accumulated minerals from the water, its ability to absorb and evaporate water decreases. We recommend changing the wick at the beginning of every season. In hard water areas, more frequent replacement may be necessary to maintain your humidifier’s efficiency.

Use only Essick Air brand replacement wicks and chemicals. To order parts, wicks and chemicals call 1-800-547-3888. The ED11 Series humidifiers use Essick Air wick # 1041. Only the Essick Air evaporative wick guarantees the certified output of your humidifier. Use of wicks other than Essick Air brand will void your warranty as well as the certification of output and may reduce the output of your humidifier.

2

Page 2
Image 2
Essick Air ED11 800, ED11 910 manual General Safety Instructions, Introduction

ED11 910, ED11 800 specifications

Essick Air is known for its commitment to quality and reliability in the realm of evaporative coolers, and the ED11 800 and ED11 910 models are prime examples of their innovative engineering. These units represent a formidable blend of performance, efficiency, and modern design, tailored to meet the cooling needs of various environments.

The Essick Air ED11 800 is designed to provide effective cooling for spaces up to 1,200 square feet. One of its standout features is the powerful 1/2 HP motor, which allows for optimal airflow and temperature control. The ED11 800 utilizes a unique, high-density evaporative media that maximizes the cooling process while minimizing water usage. This not only enhances energy efficiency but also creates a more environmentally friendly cooling solution compared to traditional air conditioning systems.

In terms of technology, the ED11 800 is equipped with a convenient, adjustable airflow system. Users can customize the direction and intensity of the airflow, ensuring that cooling is directed exactly where it is needed most. Additionally, the model features a built-in large water reservoir, which allows for extended operation without frequent refills.

On the other hand, the Essick Air ED11 910 offers a higher cooling capacity suitable for larger spaces of up to 1,500 square feet. Similar to the ED11 800, this model boasts a robust motor and efficient evaporative media. The ED11 910 takes it a step further with its advanced digital control panel, which offers intuitive programming and an easy-to-read display. Users can set precise temperature levels and monitor settings such as fan speeds and timer functions, providing a higher level of control over their indoor climate.

Both models are designed with the user in mind, featuring a sleek, modern aesthetic that fits seamlessly into various settings, from homes to commercial spaces. They are also easy to transport, equipped with durable wheels that facilitate movement from one room to another or even outdoors.

In conclusion, the Essick Air ED11 800 and ED11 910 are excellent options for individuals seeking efficient and effective evaporative cooling solutions. With their advanced technologies, user-friendly features, and commitment to performance, these models continue to uphold Essick Air’s reputation as a leader in the cooling industry. Investing in either model ensures a comfortable environment, even in the warmest months.