12
PERFORMANCE DATA SHEETSBase Grille Water Filtration System
Model WF-NL300/NL300 Capacity 300 Gallons (1136 Liters)
Model WF-L500/L500 Capacity 500 Gallons (1893 Liters)
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concen tration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Stand ards 42 and 53.
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp.= 63°F (17.2°C).
■It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
■Model WF-NL300: Change cartridge at least every 6m onths.
Use replacement cartridge NL300, part #4396508.
2010 suggested retail price of $34.99 U.S.A./$44.95 Canada.
Prices are subject to change without notice.
■Model WF-L500: The filter monitor system measures the amount
of water that passes through the filter and alerts you to replace
the filter. When 90% of the filter’s rated life is used, the filter
indicator light changes from green to yellow. When 100% of the
filter’s rated life is used, the filter indicator light changes from
yellow to red, and it is recommended that you replace the filter.
Use replacement cartridge L500, part #4396508.
2010 suggested retail price of $34.99 U.S.A./$44.95 Canada.
Prices are subject to change without notice.
■The product is for cold water use only.
■Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system.
■Refer to the “Assistance or Service” section for parts and service
availability or for the Manufacturer’s name, address and
telephone number.
■Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
■Note that while the testing was performed under stan dard
laboratory conditions, actual performance may vary. Systems
must be installed and operated in accordance with
manufacturer’s recommended procedures and guidelines.
System tested and certified by NSF International against
NSF/ANSI Standard 53 for the reduction of Lead; and
against Standard NSF/ANSI 42 for the reduction of Taste
and Odor, Chlorine Class I.
Substance
Reduction Min. Required %
reduction Average
Influent mg/L Influent Challenge
Concentration Max. Effluent
mg/L Product
Water mg/ L Min.%
Reduction Average%
Reduction
Chlorine Taste/Odor ≥50% 1.9 2.0 mg/L ± 10% 0.05 0.05 97.4 97.4
Contaminant
Reduction Max. Permissible
Concentration Average
Influent mg/L Influent Challenge
Concentration Max. Effluent
mg/L Product
Water mg/ L Min.%
Reduction Average%
Reduction
Lead: @ pH 6.5
Lead: @ pH 8.5 0.01 mg/L
0.01 mg/L 0.15
0.15 0.15 mg/L ± 10%
0.15 mg/L ± 10% 0.001
0.003 0.001
0.001 99.30
97.90 99.30
99.00
Application Guidelines/Water Supply Parameters
Water Pressure
Water Temperature
Rated Service Flow
30 - 120 psig (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 gpm (1.9 Lpm)
® NSF is a registered trademark of NSF International.