Electrical Control Module 20A Power Conditioner
ETA-ECM20, ETA-ECM20M SPECIFICATIONS
General
Type:
Power Requirements:
Power Consumption:
RoHS Compliant:
Safety Approval:
Panel
Switched Outlets:
Spike & Surge Suppression:
Manual Override:
Extreme Voltage Shutdown:
Connectors:
Fuse Protection:
DCV Remote Trigger:
Remote Trigger:
Status Signals:
Indicators:
AC Mains Interconnect:
Technical Data:
Current Rating:
Operating Voltage:
High Voltage Surge Protection:
Spike & Surge Suppression:
Low Voltage Protection:
Spike Protection Modes:
Minimum Spike Clamping Voltage:
Maximum Spike Clamping Voltage:
Maximum Spike Clamping Response Time:
Spike Clamping Voltage @ 100A:
Maximum surge current:
Energy Rating @ 2ms:
Noise Attenuation EMI/RFI Sequencer:
Temperature Range:
Humidity Range:
Mechanical:
Chassis Finish:
Mounting:
Dimensions:
Unit Weight:
Power Conditioner Suppressor Module 120V 60Hz
.5W Yes
MET (UL 1449 Code)
Two, 20A
Slide switch
5 Position Phoenix Euro Block Style
20A Slow Blow
5 – 24DCV
SPST Contact
Output for Voltage and Current Data
Incoming AC, Active, AC Fault
15 amps
102 - 132 VAC
Trigger at 133 VAC, 1ms typically
(When Used With
Trigger 101 VAC, 1ms typically
(When Used With
460 VRMS @ 3,000 amps
6000V
1nanosecond 1250Vp for 20µs 6,500 amps
600Joules
10 dB @ 10 kHz, 40 dB @ 100 kHz, 100 dB @ 10 MHz
5º to 35º C
5% to 95% R.H.
Black
#8 5/16” self tapping screws
3.0" H x 8.5" L x 3.5" W (7.6cm x 21.6 cm x 8.9cm)
©2009 ETA Systems All rights reserved. ETA003568 RevA 05/09
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
– 4 – | ETAsys.com |
Specifications are subject to change without notice.