INSTRUCTIONS TO REPLACE LIGHT TUBE LAMP (Reference diagrams above.)
1.Extend and hold light tubes, turn cap clockwise and pull to remove cap.
2.With light tube three quarters of full extension, insert index finger in light source hole at base of lamp, gently push bulb and socket through the cap's hole and replace lamp.
3.Reset socket with white mark on top, opposite light source hole, gently force lamp and socket back into light tube to a firm fit. (It may be necessary to joggle socket with one hand and guide with finger in light source hole to get proper placement.)
4.Hold light tube and snap cap back into place. Twist cap
NOTE: Replacement lamp is a standard 120 volt, 4 watt incandescent lamp. (Christmas tree lamp)
Thank you for considering and purchasing an ETA Conditioned Power Distribution unit.
By listening to our large base of present and past customers, and drawing upon many years of experi- ence in design and solving high amperage lighting and conditioned power distribution needs, ETA has developed an extensive line of Audio Conditioned Power Distribu- tion units to protect a broad range of sensitive electronic equipment.
ETA offers a complete line of power conditioning units in addition to the PD9L model. The complete product line includes 12 models of professional Audio Conditioned Power Distribution units that are UL listed and include features such as sequential power up/power down, high amperage output, and AC voltage regulator units.
SPECIFICATIONS: |
|
|
|
Input Voltage | 120V AC | ||
|
|
|
|
Spike protected | Line to neutral, neutral | ||
to | ground, line to ground | ||
|
|
|
|
UL 1449 suppressed | 395V | ||
voltage rating |
|
|
|
|
|
|
|
Response time | <1NS Typical | ||
|
|
|
|
Operating temp. range | – 40° to +158° F | ||
|
|
|
|
Maximum energy dissipation | 450 joules (3 x 150) | ||
|
|
|
|
Maximum surge current | 12000A | ||
|
|
|
|
Maximum surge voltage | 6000V | ||
|
|
| |
Noise attenuation | Transverse up to 20 dB | ||
(1.5 kHz to 200 mHz ) |
|
|
|
SM5599 | All designs and specifications are subject to change without notice. Copyright © 2004 ETA Systems. |
|