7 Disposal
The customer/enduser is obliged to take care for the disposal within the legal regulations.
8 Trouble shooting
Failure | Problems | Correction |
no function | wrong wiring, fuses, current supply | check it |
no bistable behaviour | wrong mounting of the housing | rise distance |
the switch is always closed | power switch: low current | use it as a |
(740.0060) | remove resistor R1 | |
the switch opens spontane- | load is too high | use an isolating switch amplifier |
ously (miniswitch) | temperature is too high | use a heat protection plate |
9 Technical Data
General Data
Hysteresis ca. [mm]
on basic pipe | on heating jacket | |
710.104/2XX | 6 | 15 |
710.100 | 10 | 20 |
710.110...160 | 15 | 25 |
| Cable gland downwards | |
|
| IP65 |
|
| Alu/Makrolon |
|
| with strap retainers |
| (Accesories s. page 2) | |
| Makr.: 82x80x55/0,15 kg | |
| Alu: | 75x80x57/0,3 kg |
Design Data
Operating mode |
| max. temperature | max. temp. | ||
| of pipe | of housing | |||
|
| ||||
Power switch | Makr. | 150 °C *) | 70 °C | ||
at amb.Temp.85 °C | |||||
(Solid state |
|
| |||
Alu | 400 °C *) | 90 °C | |||
| at amb.Temp.55 °C | ||||
|
|
|
| ||
Small signal | Makr. | 150 °C *) | 120 °C | ||
at amb.Temp.120 °C | |||||
switch |
|
|
|
| |
| 500 °C *) |
|
| ||
(Reed) | Alu | 120 °C | |||
| at amb.Temp.70 °C |
*)Insulate between housing and pipe above 150 °C in pipe
(>260 °C for 740.0065NA)
Electrical data power switch |
|
| Electrical data miniswitch |
|
Operating voltage nominal: | 24 V~ to 230V~ | Operating voltage limit: | 400 V= / 230 V~ | |
Operating voltage limit: | 250 | V~ | Operating current limit: | 0,5 mA |
Load current nominal: | 24 mA~ to 2,5 | A~ | Rupturing capacity UxImax: | 5 W |
6 mA~ |
|
| ||
max. power limit: | 550 VA |
|
|
-1) Take into account that none of the three parameters Umax, Imax, Pmax may be exceeded!
PHÖNIX Messtechnik GmbH, Salzschlirferstr. 13,