How to MaintainYour Vacuum Cleaner

How to MaintainYour Vacuum Cleaner

! Make sure vacuum cleaner is turned off and power cord is unplugged!Motor can become hot with normal use. Make sure vacuum cleaner is turned off and power cord is unplugged

Maintain Brush Roll – Call Eureka Customer Service HELPLINE – Part number 62365-4

Motor can become hot with normal use.

Do not remove end caps. Remove hair and threads from brush roll periodically.

Check EXT-U Belt if Cut or Out of Shape – Part number 61120C

!Avoid touching the motor shaft when checking brush roll belt.

1)Use handle release to lower handle flat onto floor (Fig. 1).

2)Remove 2 screws from the front side of brush roll cover (Fig. 2).

3)Lift and remove brush roll cover (Fig. 3).

4)Remove brush roll and belt. Thread new belt around motor shaft and brush roll (Fig. 4).

5)Insert left end of brush roll first. Make sure square on brush roll cap is in place. Pull right side of brush roll to stretch belt. Secure right end cap into base (Fig. 5).

6)Rotate brush roll 2 turns to center belt.

7)Replace brush roll cover (Fig. 2).

8)Replace 2 screws (Fig 6).

Fig. 1

Fig. 3

Fig. 5

Fig. 2

Fig. 4

Fig. 6

Change Light Bulb – Part number 57940-3
!Make sure vacuum is turned off and power cord is unplugged.

1)Lower handle to floor and remove HEPA filter (Fig. 7).

2)Unscrew the lens and remove old bulb.

3)Push in new bulb, replace lens cover and replace screw (Fig 8).

4)Replace HEPA filter and return to upright position.

Fig. 7

Fig. 8