Installation SMA Solar Technology AG
16 PBL-SMC-NR-IXX082210 Installation Guide
3 Installation
1. If present: remove the SMA Power Balancer wiring from the Sunny Mini Central
2. If necessary, replace the screw connection of the
optional cable feed-through by the provided seal
(B) so that the housing is sealed.
3. Remove the screw connection for the cable feed-th-
rough from the housing opening.
4. nsert the cable set (E) through the housing opening
from the inside and fasten with the counter nut (D)
from the outside.
The toothing of the counter nut must face toward
the housing.
DANGER!
Danger to life due to high voltages in the Sunny Mini Central!
Open the Sunny Mini Central as described in the Sunny Mini Central installation
guide.
NOTICE!
Electrostatic discharges can damage the Sunny Mini Central!
Ground yourself before you touch components in the Sunny Mini Central.
Avoid coming into contact with components' connections and plug contacts.
1
2