Page 5
Image 5
Changing the Pre-Motor Filter
Wash once a month or when suction appears reduced
Warning: Allow 24 hours for drying before replacing in unit.
Fig. A

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

9.Reassemble the debris screen to the HEPA filter cartridge and replace into dust cup (container). Ensure that the filter assembly is completely seated inside the dust cup (container).

10.Attach the dust cup (container) to the vacuum.

PLEASE NOTE: The white pleated filter material in the HEPA Dust Cup Filter will discolor over time -This is NORMAL and will NOT affect the performance of the filter. If the HEPA Dust Cup Filter

is properly "TapCleaned” after each use and suction does not return to 100%, then we suggest that the HEPA filter be “TapCleaned” vigorously until no

more dust can be removed, then rinsed under the faucet and allowed to dry for 24 hours before refitting into the vacuum. (Fig. A) This should be done once a month or when suction appears to be reduced.

CAUTION: The suction hole must be open, free of any obstructions at all times. Otherwise, the motor will overheat and could become damaged.

Important: Do NOT use the HEPA filter cartridge without the debris screen in place.

Changing the Pre-Motor Filter

Filter should be cleaned at least twice a year or when it becomes visibly solid.

Always operate the cleaner with the filter installed.

Disconnect from electrical outlet before cleaning the filter.

1.Lift dust cup handle to remove dust cup.

2.Remove the filter from the filter grill.

3.Replace with a new filter and reinstall in vacuum.

Changing the Micro-Exhaust Filter

1.Remove the exhaust filter grill by pulling the locking tabs towards you.

2.Remove the used micro-exhaust filter.

3.Insert a new micro-exhaust filter and replace the filter grill.

IMPORTANT: Both the Pre-Motor and the Micro Exhaust filters should be replaced every 6 months or sooner if required.

IMPORTANT: All filters should be checked regularly for signs of damage, preferable after each cleaning task. The filters must be replaced immediately if they become damaged.

Always disconnect the vacuum from the electrical outlet when checking the filters.

Assembling Your Vacuum Cleaner

Note: Always remove the power plug from the wall outlet before assembling or removing accessories.

1.Attaching the Flexible Hose into the Vacuum

Connect the flexible hose into the air intake duct. Push in until you hear a “click”, indicating it is in its locked position.

To remove the flexible hose reverse the operation.

Air Intake Duct

2.Fitting the Telescopic Tube to the Curved Wand / Hose Extension

Push the telescopic tube into the curved wand / hose extension, as shown in the illustration below.

3.Extending the Chrome Telescopic Tube

Push forward on the plastic button and pull the inner chrome tube outward.

Plastic

Knob

4.Fitting the Floor to Carpet Brush or the Air Driven Turbo Brush to the Telescopic Tube

Push the telescopic tube into the desired floor brush as show in the illustration below.

Telescopic

Tube

Floor to Carpet

Nozzle

5.Air Driven Turbo Brush

The efficiency of your Air Driven Turbo Brush depends on the bristle brush rotating at high speed. Strong air suction is needed to accomplish this. In order to endure that maximum air suction is maintained, please read the following instructions:

Empty the Dust Cup frequently during use.

Always “TapClean” the HEPA dust cup filter and debris screen each time the dust cup is emptied.

Ensure that the rotating bristle brush is kept free of hair and string.

Inspect the turbine regularly to ensure that the air passage is free of dirt and debris.

Hand Held Air Driven

Turbo Brush

Air Driven Turbo

Brush

7

4

Page 5
Image 5
Euro-Pro EP722 Changing the Pre-Motor Filter, Changing the Micro-Exhaust Filter, Assembling Your Vacuum Cleaner