| | 1. | Power cord not firmly plugged into | 2. | Check fuse or breaker. Replace |
| VACUUM WILL | | outlet. | | fuse/reset breaker. |
| 2. | No power in wall outlet. | 3. | Call 1-800-798-7398. |
| NOT OPERATE |
| 3. | Needs servicing. | 4. | Turn the unit off and unplug from |
| |
| | 4. | Thermostat has tripped. | | outlet. Allow unit to cool down, |
| | | | | then restart. |
| | | | 1. | Empty and clean dust cup. |
| | | | 2. | Turn unit off and unplug from |
| VACUUM WILL | 1. | Dust cup is full. | | wall outlet. Remove Dust Cup |
| 2. | Unit clogged. | | Filter and check for object(s) in |
| NOT PICK-UP OR | 3. | Dust Cup Filter needs cleaning or | | air duct and remove. |
| SUCTION POWER | | replacing. | 3. | Clean or replace Dust Cup |
| IS WEAK | 4. | Flexible Hose/Extension Tubes | | Filter. |
| | | clogged | 4. | Turn unit off and unplug from |
| | | | | wall outlet. Check for objects in |
| | | | | deluxe hose/extension tube. |
| | | | | |
| TURBO BRUSH | 1. | Dust cup full. | 1. Empty and clean dust cup. |
| 2. | Rotating brush or elbow |
| DOES NOT | 2. | Clear obstructions. |
| | obstructed. |
| ROTATE OR | | 3. | Call 1-800-798-7398. |
| 3. | Belt broken. |
| ROTATES | 4. | Clear obstruction. |
| 4. | Hose obstructed. |
| SLOWLY | 5. Clean or replace dust cup filter. |
| 5. | Dust cup filter clogged. |
| | | |
| | 1. | Dust cup is full. | 1. | Empty and clean dust cup. |
| DUST ESCAPING | 2. | Dust Cup Filter is not installed |
| 2. Review Dust Cup Filter |
| | correctly. |
| FROM VACUUM | | | instructions. |
| 3. | There is a puncture/hole in Dust | |
| | 3. | Replace Dust cup filter. |
| | | Cup Filter. |
| | | | |
| | | | | |
| VACUUM, HOSE | | | 1. | Remove hose and/or brushes. |
| 1. | Hose clogged. | | Remove obstruction from hose |
| OR BRUSHES | |
| 2. | Dust cup is full. | | and /or brush. |
| WILL NOT PICK-UP | |
| | | 2. | Empty and clean dust cup. |
| | | |
FOR REPLACEMENT FILTER INFORMATION
for Model HV118
Call: 1 (866) 98SHARK (74275)
Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time
Or visit our website: www.sharkvac.com
For Technical Support
WARNING: To reduce the risk of fire, electrical shock, or injury:
1.Do not leave vacuum cleaner unattended when it is plugged in. Unplug from
outlet when not in use and before cleaning or servicing.
2.To reduce the risk of electric shock – do not use outdoors or on wet surfaces.
3.Do not allow children to use as a toy. Close attention is necessary when used by or near children.
4.Use only as described in this manual. Use only manufacturer’s recommended attachments.
5.Do not use with damaged cord or plug. Do not use vacuum cleaner if it has been dropped, damaged, left outdoors, or dropped into water. Return appliance to EURO-PRO Operating LLC. for examination, repair or adjustment.
6.Do not pull or carry by cord. Do not use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Do not run appliance over cord. Keep cord away from heated surfaces.
7.Do not unplug by pulling on cord. To unplug, grasp the plug, not the power cord.
8.Do not handle plug or vacuum cleaner with wet hands. Do not use outdoors or on wet surfaces.
9.Do not put any objects into openings. Do not use with any opening blocked and do not restrict airflow. Keep all openings free of dust, lint, hair, and anything that may reduce airflow.
10.Keep hair, loose clothing, fingers and all parts of body away from openings and moving parts.
11.Do not pick up hot coals, cigarette butts, matches or any hot, smoking, or burning objects.
12.Do not pick up hard or sharp objects such as glass, nails, screws, coins, etc.
13.Do not use without all filters in place.
14.Turn off all controls before plugging or unplugging vacuum cleaner.
15.Use extra care when vacuuming on stairs.
16.Do not pick up flammable or combustible materials (lighter fluid, gasoline, kerosene, etc.) or use in the presence of explosive liquids or vapor.
17.Do not pick up toxic material (chlorine bleach, ammonia, drain cleaner, etc.).
18.Do not use in an enclosed space filled with vapors given off by oil based paints, paint thinner, moth proofing substances, flammable dust, or other explosive or toxic vapors.
19.Always unplug this appliance before connecting or disconnecting vacuum hose.
20.Use only on dry, indoor surfaces.
21.Do not use for any purpose other than described in this user’s guide.
22.Use only extension cords UL-rated or cUL at 15 amperes. extension cords rated for less amperage may overheat. Care should be taken to arrange the cord so that the cord cannot be pulled or tripped over.
23.Store your appliance indoors in a cool, dry area.
24.Keep your work area well lit.
25.Do not immerse the mini canister into water or other liquids.
26.Keep end of hose, wands and other openings away from your face and body.
for Model HV118
Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time
Please Note:
The HEPA Dust Cup Filter is washable. It should, however, be replaced every six (6) months to ensure peak performance of your vacuum.
The Exhaust Filter is washable. It should however be replaced every three (3) months to ensure peak performance of your vacuum.
Important:
Make sure that ALL filters are completely dry (air dry only for 24 hours) before re- installing back in the mini canister vacuum.
SAVE THESE INSTRUCTIONS
For Household Use Only
WARNING: To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install
the proper outlet. Do not modify the plug in any way.