4)Wall Mount, aim to left: Remove the iron case from the supporting bracket by using screw

driver to loosen the two screws, which connect the iron case to the supporting bracket. Turn the iron case in 90-degree and mount into

the supporting bracket again by changing the screw holes in order to keep the screw indicator on the top side.

qConnect the video output of the camera to a B/W monitor (ED100) or a color monitor (ED200), or other video device through a 75 ohm type coaxial cable with BNC female connector at cable extension.

rConnect the DC+12V regulated power source to the DC12V Power-in jack with 2mm, center+, outer- plug.

sPut the dome plastic cover back into the Dome Camera.

IV. Specifications

 

 

ED100

 

ED200

Pickup Device:

1/3 inch B/W interline

1/3 inch Color

 

transfer CCD

interline transfer CCD

Picture Element:

510x492(/E,EIA)

510x492(/N,NTSC)

 

500x580(/C,CCIR)

500x580(/P, PAL)

Horizontal resolution:

420 TV lines (EIA)

380 TV lines (NTSC)

 

400 TV lines (CCIR)

340 TV lines (PAL)

Sensitivity:

0.5 lux/F=2.0

2.5 lux/F=2.0

S/N ratio:

Over 48 dB

Over 48dB

Electronic shutter:

Up to 1/10,000

Up to 1/100,000

Gamma Correction:

> 0.45

 

0.45

Video output:

1.0Vp-p,75 ohm

1.0Vp-p,75 ohm

Power source:

12VDC+/-10%,

12VDC+/-10%,

 

150mA Max.

250mA Max.

Sync. Mode:

Internal Sync.

Internal Sync.

Lens Mount:

M12xP0.5

M12xP0.5

Dimension:

106mm Dia.x 85mm H.

106mm Dia.x85mm H.

Operating Temperature:

-10oC to +50o C

-10oC to +50o C

ED100 Series

ED200 Series

INSTRUCTION

MANUAL

Page 1
Image 1
EverFocus ED200 Series, ED100 Series instruction manual Instruction Manual, IV. Specifications, ED100 ED200