EDR910_1610_ma_en_rev1 00 - 48 -
3.11.3 NO HDD
The DVR detects when both harddisks are removed, switched off or not detected. Define
the alarm reactions in this menu item:
(1) BUZZER: By selecting “ENABLE”, the buzzer is activated.
(2) ALARM OUTPUT: Output relay activation.
1 Output relay 1 switches upon alarm.
NONE no output relay reaction upon alarm.
(3) ALARM DURATION: Alarm duration adjustment from 1~99 seconds or permanent.
(4) NETWORK ALARM: YES: Network alarm activated (for settings refer to
NETWORK menu)
Network alarm reception requires optional PowerCon
software.
NO: No network alarm transmission
(5) EMAIL: YES: Alarm email transmission (for settings refer to
NETWORK menu).
NO: No email alarm transmission.
WARNING SETUP MENU
FAN FAULT BUZZER ENABLE
HDD TEMP. ALARM OUTPUT 1
NO HDD ALARM DURATION PERMANENT
HDD FULL NETWORK ALARM NO
EMAIL NO