Everpure EV3112-81 installation and operation guide Selecting A Mounting Location, Replacement

Models: EV3112-81

1 4
Download 4 pages 34.83 Kb
Page 1
Image 1
 Installation and Operation Guide

Insurice Filter Systems Installation and Operation Guide

Insurice Filter Systems

Selecting A Mounting Location

1.Give consideration to the weight of the unit when operating (filled with water). Operating weights of the Insurice Systems are:

Single System - 9 lbs. (4.0 kg.)

Twin System - 19 lbs. (8.5 kg)

Triple System - 27 lbs. (12 kg)

Quad System - 36 lbs. (20 kg)

2.The location should allow for:

Minimum clearance of 2-1/2” under the cartridge(s) so it can be lowered for removal and re- placement.

Adequate space for “in” and “out” water line connections.

Be near a drain for flushing and near a 110V outlet if the accessory (sold separately) Everguard Low Pressure Alarm is used. See Figures 1-4.

3.If possible, keep at least 6” available to the left and the right of the Insurice System in the event poor quality water conditions require the installation of the optional Everpure K-Series Prefilter.

Operating Specifications*

Combined Model Name

Replacement

Flow Rate

Capacity

Cartridge

 

 

 

 

 

 

 

Insurice Single - i2000

i2000

1.67 gpm (6.3 lpm)

9,000 gal (34,000 L)

Insurice Single - i20002

i20002

1.67 gpm (6.3 lpm)

9,000 gal (34,000 L)

Insurice Single - i4000

i4000

1.67 gpm (6.3 lpm)

12,000 gal (45,420 L)

Insurice Single - i40002

i40002

1.67 gpm (6.3 lpm)

12,000 gal (45,420 L)

Insurice Twin - i2000

i2000

3.3 gpm (12.6 lpm)

18,000 gal (68,000 L)

Insurice Twin - i20002

i20002

3.3 gpm (12.6 lpm)

18,000 gal (68,000 L)

Insurice Twin - i4000

i4000

3.3 gpm (12.6 lpm)

24,000 gal (90,840 L)

Insurice Twin - i40002

i40002

3.3 gpm (12.6 lpm)

24,000 gal (90,840 L)

Insurice Triple - i2000

i2000

5.0 gpm (18.9 lpm)

27,000 gal (102,000 L)

Insurice Triple - i20002

i20002

5.0 gpm (18.9 lpm)

27,000 gal (102,000 L)

Insurice Triple - i4000

i4000

5.0 gpm (18.9 lpm)

36,000 gal (136,260 L)

Insurice Triple - i40002

i40002

5.0 gpm (18.9 lpm)

36,000 gal (136,260 L)

Insurice Quad - i2000

i2000

6.6 gpm (25 lpm)

36,000 gal (136,260 L)

Insurice Quad - i20002

i20002

6.6 gpm (25 lpm)

36,000 gal (136,260 L)

Insurice Quad - i4000

i4000

6.6 gpm (25 lpm)

48,000 gal (181,680 L)

Insurice Quad - i40002

i40002

6.6 gpm (25 lpm)

48,000 gal (181,680 L)

*For individual cartridge specifications, refer to cartridge literature. Temperature: 35-100°F (2-38°C)

Pressure: 10 - 125 psi (0.7 - 8.6 bar), non-shock For cold water use only.

Figure 1 – Insurice Single System

Figure 2 – Insurice Twin System

Figure 3 – Insurice Triple System

Figure 4 – Insurice Quad System