| PERFORMANCE |
|
WATER TREATMENT PRODUCTS | DATA SHEET |
|
|
| |
1040 Muirfield Drive • Hanover Park, IL 60133 • 630.307.3000 • FAX 630.307.3030 |
|
|
|
| |
|
|
|
MH AND MH2 WATER FILTERS |
|
|
MH Cartridge Part No. EV9613-01 (1-pack)
Part No. EV9613-06 (6-pack)
MH2 Cartridge Part No. EV9613-21 (1-pack)
Part No. EV9613-26 (6-pack)
FEATURES
•Finely polishes treated water to premium quality.
•Reduces chlorine taste and odor.
•Reduces dirt, rust, asbestos fibers, and other particulates including oxidized iron, manganese, and sulfides.
•Reduces parasitic protozoan cysts such as Giardia, Entamoeba, and Cryptosporidium.
•Reduces common earthy, moldy, fishy tastes and odors
•Inhibits limescale
•MH2 cartridges are treated with bacteriostat to effectively reduce the growth of bacteria on the filter media. Not Performance Tested or Certified by NSF.
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF/ANSI*
This system has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.
Substance | Influent Challenge | Max. Permissable Product | Reduction | Minimum | Average | |
Concentration | Water Concentration | Requirements | Reduction | Reduction | ||
| ||||||
Standard |
|
|
|
| ||
Chlorine | 2.0 mg/L ± 10% |
| ≥ 50% |
| 87.8% | |
Particulate, |
|
|
|
|
| |
Class I | at least 10,000 |
| ≥ 85% |
| 99.2% | |
particles 0.5 | particles/mL |
|
| |||
|
|
|
| |||
to <1 µm |
|
|
|
|
| |
|
|
|
|
| ||
Standard |
|
|
|
| ||
Turbidity | 11 ± 1 NTU | 0.5 NTU |
| 95.4% | 97.2% | |
Asbestos | 107 to 108 fibers/L > 10 |
| 99% | 99.87% | 99.87% | |
micrometers in length |
| |||||
|
|
|
|
| ||
Cyst | Minimum 50,000/L |
| 99.95% | 99.99% | 99.99% |
*Tested using flow rate = 1.67 gpm; pressure = 60 psig; pH = 7.5 ± 1; temp. = 20° ± 3°C
† NTU = Nephelometric Turbidity Units
GENERAL INSTALLATION/OPERATION/MAINTENANCE REQUIREMENTS
•Install vertically with cartridge hanging down
•Use minimum length of tubing possible
•Flush to drain for 5 minutes at full flow
•Replace cartridges when capacity is reached or when flow becomes too slow, but at least annually.
OPERATING SPECIFICATIONS
•Pressure requirement:
•Temperature:
NSF Listed Systems | Max. Flow Rate | Capacity |
| Space Requirements* |
QC7I Single - MH | 1.67 gpm (6.3 lpm) | 9,000 gal (34,050 | L) | 29" H x 51⁄2" W x 5" D |
QC7I Single - MH2 | 1.67 gpm (6.3 lpm) | 9,000 gal (34,050 | L) | 29" H x 51⁄2" W x 5" D |
QC7I Twin - MH | 3.3 gpm (12.6 lpm) | 18,000 gal (68,100 L) | 25" H x 11" W x 5" D | |
QC7I Twin - MH2 | 3.3 gpm (12.6 lpm) | 18,000 gal (68,100 L) | 25" H x 11" W x 5" D | |
QC7I Triple - MH | 5.0 gpm (18.9 lpm) | 27,000 gal (102,150 L) | 25" H x 15" W x 5" D | |
QC7I Triple - MH2 | 5.0 gpm (18.9 lpm) | 27,000 gal (102,150 L) | 25" H x 15" W x 5" D | |
QC7I Quad - MH | 6.6 gpm (25.3 lpm) | 36,000 gal (136,200 L) | 29" H x 24" W x 5" D | |
QC7I Quad - MH2 | 6.6 gpm (25.3 lpm) | 36,000 gal (136,200 L) | 29" H x 24" W x 5" D |
* Includes 21⁄2” clearance under unit for cartridge change
SPECIAL NOTICES
•Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
•This drinking water system must be maintained according to manufacturer’s instructions, including replacement of filter cartridges.
•Do not use with water that is microbiologically unsafe, or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
•The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.
•Check for compliance with state and local laws and regulations.
•Tested under standard laboratory conditions as specified above. Actual performance may vary depending on influent water conditions.
•To determine NSF Model Name, combine HEAD NAME + CARTRIDGE NAME. Refer to www.nsf.org to verify certification.
System Tested and Certified by NSF International against
NSF/ANSI Standards 42 and 53 for the reduction of:
Standard No. 42 —
Aesthetic Effects
Chemical Reduction
Taste and Odor
Chlorine
Mechanical Filtration
Particulate Class I: 99.2% reduction of particles
Standard No. 53 — Health Effects Mechanical Filtration
Turbidity Cyst Asbestos
Buyer |
| Seller |
| Date |
©2005 Everpure, LLC |
|
|
|