Specifications
Dimensions
37"W x 27"H x 15"D
Weight
Dry Weight
mounting
System components should be vertically mounted on a bulkhead or stanchion within reasonable proximity to each other and the bypass header assembly. A minimum of
13 inches of overhead clearance is required above the feeder assembly for easy removal of the disposable bromine cartridge. For convenience, the instruction plate with operating procedure should be bulkhead mounted adjacent to the proportioning bromine feeder.
SIZING AND ORDERING A
PROPORTIONING BROMINATOR
For each distiller / watermaker served, determine the capacity in gallons per day. Using this figure, calculate the discharge in gallons per minute. For example: 26,000 gpd /24, /60 = 18.0 gpm. Choose a part number corresponding to these flow rates:
| ||
BROMINATOR | BROMINATOR | REPLACES |
FLOW RATE (gpm) | PART NO. | PART NO. |
|
|
|
16 - 24 | 169106 | EV906421 |
25 - 35 | 169107 | EV906422 |
|
|
|
NOTES
A potable water storage tank should be treated whenever it is filled from a shore source, or whenever there is no measurable bromine residual in the tank. A measurable bromine residual will insure the water is safe to drink. See our recirculating brominator data sheets for this application.
PLUMBING TERMINATIONS
The proportioning bromine feeder is flanged per
BYPASS HEADER
AND VALVE
(SUPPLIED BY
INSTALLER)VALVE (SUPPLIED BY
INSTALLER)
THICKNESS OF GASKET
VALVE
(SUPPLIED BY
INSTALLER)
WATER METER
FLEXIBLE
TUBING
HOSE
CLAMPS
BYPASS HEADER
ASSEMBLY
DUAL FEED
VALVE
ASSEMBLY
FLANGE AND
GASKET
(SUPPLIED BY
INSTALLER)
23" MAX
ALLOW 13" MINIMUM FROM TOP OF FEEDER TO OVERHEAD FOR REMOVAL OF CARTRIDGE
FEEDER
ASSEMBLY