Excell Precision VR2300 operation manual Problem Cause, At pump

Models: VR2300

1 22
Download 22 pages 2.19 Kb
Page 19
Image 19

PROBLEM

CAUSE

Will not draw

Wand not in low pressure.

 

chemicals

Chemical filter clogged.

 

 

Chemical screen not in chemical

 

Chemical too thick.

CORRECTION

See How to Use Wand paragraph in the Operation Section.

Clean filter.

Insure end of chemical hose is fully submerged into chemical.

Dilute chemical. Chemical should be the same consistency as water.

 

 

Pressure hose is too long

Lengthen water supply hose

 

 

 

instead of pressure hose.

 

 

Chemical build up in chemical

Have parts cleaned or replaced

 

 

injector.

by AWSC.

 

 

 

 

No or low

 

Worn seal or packing

Have replaced by AWSC.

pressure (after

 

 

 

 

Worn or obstructed valves.

Have replaced by AWSC.

period of

 

 

Worn unloader piston.

 

normal use)

 

Have replaced by AWSC.

 

 

 

 

 

 

Worn E-Z start valve.

Have replaced by AWSC.

Water leaking

 

Worn or broken o-ring.

Check and replace.

at gun/wand

 

 

 

connection

 

Loose hose connection.

Tighten.

 

 

 

 

Water leaking

 

Loose connections.

Tighten.

at pump

 

 

 

 

Piston packings worn.

Have replaced by AWSC.

 

 

 

 

 

 

 

 

Worn or broken o-rings.

Have replaced by AWSC.

 

 

 

 

 

 

Pump head or tubes damaged

Have replaced by AWSC.

 

 

from freezing.

 

Pump Pulsates

 

Nozzle obstructed.

Clean nozzle with paper clip or

 

 

 

nozzle cleaning tool, pour water

 

 

 

into nozzle end to flush out ob-

 

 

 

struction.

19- ENG

D27935

Page 19
Image 19