Operation

Push the lever forward and down to disengage the brake.

The unit must be tied down and brake engaged when transporting.

Ignition Switch

Located on right console (see Figure 6).

The ignition switch is used to start and stop the engine. The switch has three positions “OFF”, “ON” and “START”. Insert key into switch and rotate clockwise to the “ON” position. Rotate clockwise to the next position to engage the starter (key must be held against spring pressure in this position). Allow the key to return to the “on” position immediately after the engine starts.

Figure 7

1. Off

3. Start

2.On

Note: Brake must be engaged, motion control levers out (neutral lock position) and PTO switch disengaged to start engine. (It is not necessary for the operator to be in the seat to start the engine.)

Hour Meter

Located on the right console in the message display (see Figure 6 and Figure 8).

The hour meter records the number of hours that the engine has run.

Figure 8

1.LCD Indicators

2.Low fuel indicator light

3.Fuel level bar display

4.Low voltage indicator light

5.Hour/Voltage display

The hour meter is recording when the decimal point is flashing in Hour/Voltage display.

Hours are displayed when the key is off or when the machine is running.

Note: If the ignition key is turned to the “ON” position for a few seconds before cranking the engine, the battery voltage will display in the area where the hours are normally displayed.

Note: The LCD indicators appear when each control meets the “safe to start” mode (e.g. the indicator turns on when the operator is in the seat.)

Fuel Shut-Off Valve

Located behind and below the seat.

The fuel shut-off valve is used to shut off the fuel when the machine will not be used for a few days, during transport to and from the jobsite, and when parked inside a building.

Align valve handle with the fuel line to open. Rotate 90° to close.

Fuel Gauge

Located on the right console in the message display (see Figure 6 and Figure 8).

The fuel level is shown on a bar display. The indicator light appears when the fuel level is low (approximately one gallon remaining in the tank).

22

Page 22
Image 22
Exmark 312, 0 manual Ignition Switch, Hour Meter, Fuel Shut-Off Valve, Fuel Gauge

0, 312 specifications

Exmark has long been synonymous with excellence in the world of lawn care and landscaping, and their 000 & higher, 0,312 series is no exception. Engineered for both professional landscapers and passionate homeowners, this series brings together innovative technology with robust design to deliver unparalleled performance and durability.

One standout feature of this series is its powerful engine options, which ensure efficient cutting and grass handling capabilities. The engines are designed to provide consistent power and reliability, even in tough conditions. This reliability is complemented by high-quality cutting decks that deliver precision cuts and exceptional mulching abilities, ensuring that your lawn stays healthy and vibrant.

The cutting height adjustment system allows users to easily modify the height to suit various types of grass and landscaping needs. This adaptability ensures that your grass is always maintained at the optimal length for health and aesthetics. The ergonomic design of the handles incorporates comfort grips, reducing fatigue during prolonged use while providing excellent control over the machine.

Another significant aspect of the 000 & higher, 0,312 series is its advanced technology integration. Many models in this series come equipped with efficient fuel systems that enhance performance while minimizing fuel consumption. Furthermore, the inclusion of intelligent controls and monitoring systems enables users to make informed adjustments, ensuring that the equipment operates at peak performance.

The robust construction of the chassis and frame means that these machines can withstand the rigors of everyday use in various landscapes. The high-quality materials used in the manufacturing process enhance the longevity of the equipment, making it a worthy investment for those serious about maintaining their lawns.

In addition, Exmark places a strong emphasis on safety features. The series includes protective shields and easy-to-access controls that prioritize user safety without compromising on functionality. Maintenance is made simple through user-friendly designs, allowing for quick access to essential components.

In conclusion, the Exmark 000 & higher, 0,312 series presents a perfect blend of power, innovation, and user-focused features. With its reliable performance, flexible adjustment options, and sturdy design, this series continues to set the standard for excellence in lawn care equipment. Whether you’re a professional or a homeowner, the Exmark 000 & higher, 0,312 series stands ready to meet all your landscaping needs.