Surface Access Products • Maintenance and Modifications
Surface Access Products • Maintenance and Modifications
Maintenance and Modifications, cont’d
Mounting
Surface
Clamshell
Full Thread
Mounting Bolts
AAP Cables
Flat Washer
IEC Power Cord
RJ-45 Connectors
Shroud
HSA 802
Remove 16
screws
125 - 50/60 Hz 0.5A
COMPUTER
INPUT
SELECT
AUDIO

Figure 3-3 — Removing the HSA 802 from the table

17. Carefully lower the HSA enclosure into the table opening.
From the underside, bolt the clamshell to the enclosure
with the two bolts removed in step 5.

3-73-6

Figure 3-4 — Disconnecting the interior AC cable

18. Connect the IEC power cord and RJ-45 cables to the
connectors on the underside of the surface mount
enclosure.
19. To prevent wear and tear caused by cable movement,
secure the AAP cables underneath the table. See Routing
the AAP Cables in chapter 2, Installation.
Adding a Second Connector Panel
The standard HSA 800 includes one connector panel with the
associated connectors and AAP opening. Non-US/domestic
versions also have a separate AC connector panel. Future needs
may demand adding a second connector panel and, for non-
US/domestic versions, an AC panel (in effect converting the
HSA 800 into an HSA 802). Add the additional panels as
follows:
Ensure that AC power is disconnected before
servicing the HSA unit.