Surface Access Products • Installation
Surface Access Products • Installation
Installation, cont’d
2-52-4
template, you will cut an improperly-sized hole. If
you use a larger template than required, the cut will
result in gaps in the table surface on either side of
the enclosure.
The surfaces of the HSA enclosure have screws and
other protruding hardware that could damage fine
furniture. Do not rest the enclosure on unprotected
furniture.
The routing template is reusable. Do not discard the
template when the installation is complete. Save it for
installing other HSA products of the same size.
1. Locate the desired mounting location on the tabletop or
other installation surface. Mark the location.
CAUTION
Ensure that only the wooden strips contact the
furniture. Failure to do so may mar the furniture.
2. Place the mounting template assembly on the table,
centered on the mounting location. Angle the template for
the optimum positioning. If necessary, use a square to
ensure that the template is properly positioned. Extron is
not responsible for improperly-positioned HSA products.
3. Once the template assembly is positioned properly, secure
the assembly to the table with C-clamps (figure 2-2).

Figure 2-2 — Cutting the opening with a router

Wear safety glasses when operating the router.
Failure to comply can result in eye injury.
4. Using a router with a 5/8” (or 16 mm) outside diameter
guide bushing and a 1/2” (or 12 mm or 12.7 mm) diameter
straight router bit, carefully cut the opening in the table
surface.
5. Remove the C-clamps and the routing template.
The flanged edges of the top of the surface enclosure
are sharp when the HSA is removed from the table.
Exercise caution when handling to prevent personal
injury.
CAUTION
The flanged edges of the top of the surface enclosure
are bevelled to an ultra-fine thickness of less than
0.04 (4/100)” (approximately 1 mm). These edges
are soft and can be easily nicked or bent. Exercise
caution when handling and mounting the
enclosure. Mishandling can damage the appearance
of the enclosure.
6. Remove the plastic strips that protect the flanged edges of
the top of the surface enclosure. If a sticky residue
remains, remove it with a soft cloth dampened with
isopropyl alcohol.
7. Carefully lower the HSA enclosure into the hole to test the
fit. If necessary, remove the enclosure and use a file or
rasp to enlarge or smooth the edges of the opening.
8. From the underside of the table, bolt the clamshell to the
enclosure with two bolts of optimum length (included)
(figure 2-3).
9. Peel any remaining protective coating from the enclosure.