IN1606 and IN1608 Series Scaling Presentation Switcher • SIS Configuration and Control 36
X5! = Increment value dB value multiplied by ten, in 0.1 dB increments, to 
raise or lower a group fader (for example,  
100 = 10 dB)
X5@ = Password 12 digits and alphanumeric characters for user or 
admin passwords.
NOTE: / \ | * and space are invalid characters.
X5# = Verbose mode 0 = clear or none (default for Telnet connections) 
1 = verbose mode (default for RS-232) 
2 = tagged responses for queries 
3 = verbose mode and tagged for queries
X5$ = Auto switch mode 0 = disable 
1 = prioritizes the highest numbered active input 
2 = prioritizes the lowest numbered active input
X5% = Video mute on all outputs 0 = all outputs are unmuted 
1 = at least one output is muted 
2 = at least one output is muted and sync is 
      disabled
X5^ = Volume knob group number 1 = program volume 
3 = mic volume 
8 = output volume (default)
X5& =Gain or mute control 40100 = mic 1 (mix volume only) 
40000 = mic 1 (mute only) 
40101 = mic 2 (mix volume only) 
40001 = mic 2 (mute only) 
60000 = output 1 
60002 = output 2 
60004 = variable output L 
60005 = variable output R 
60006 = digital output L 
60007 = digital output R 
60008 = amplified output L (IN1608 SA only) or  
              amplified output (IN1608 MA only) 
60009 = amplified output R (IN1608 SA only)
X5* =Gain or trim level -1000 to 0 = dB value multiplied by ten, in 0.1 dB 
increments,  (for example, -100 = -10 dB) 
0 = default