IN1606 and IN1608 Series Scaling Presentation Switcher • SIS Configuration and Control 51
Command ASCII Command
(host to scaler)
Response
(scaler to host)
Additional Description
Information request
General Information IVidX!AudX! TypX#StdX1) BlkX2*...
HrtX1#VrtX1# ]
Query firmware version Qx.xx]View firmware version.
Query full firmware version *Q x.xx.xxxx]View full firmware version.
Query part number N<part number>]View the part number.
View internal temperature E20STAT} X1!] View the temperature in
degrees Celsius.
Backup or restore configuration
Save configuration to file system E1*X4%XF}Cfg1* X4%] Back up the current device
configuration.
Restore configuration from file
system
E0*X4%XF}Cfg0* X4%] Restore device configuration.
Device naming
Set unit name24 EX1$ CN}IpnX1$] Set the device name to X1$.
Set unit name to factory default24 ECN}IpnX3#] Reset the device name to the
factory default.
View unit name ECN} X1$] View the device name.
NOTES:
X! = Input selection 1-6 (IN1606) or 1-8 (IN1608 models)
X# = Input video format 1 = RGB
2 = YUV
3 = RGBcvS
4 = S-video
5 = composite
6 = HDMI
X1) = Input standard 0 = no signal detected on the current input
1 = NTSC 3.85
2 = PAL
3 = NTSC 4.43
4 = SECAM
- = not applicable (occurs when the input is active RGB,
YUV, or HDMI signals)
X1! = Internal temperature In degrees Celsius
X1# = Horizontal and vertical frequencies xxx.x
X1$ = Text label Up to 63 characters
X2* = Video output mute 0 = unmute
1 = mute video
2 = mute video and sync
X3# = Default name A combination of model name and the last 3 character pairs
of the MAC address
X4% = Config type 0 = IP config
2 = box-specific parameters