SIS Programming and Control, cont’d
IPL 250 • SIS Programming and Control
4-10
Command/response table for SIS commands (continued)
Command ASCII (Telnet)
(host to IPL) URL Encoded (Web)
(host to IPL) Response
(IPL to host) Additional description
View receive timeout E X! CE}W X ! CE| X1& , X2) , X2# , X2! ]
Configure serial pass-through
mode24
E X! * X5) * X5# * X2! CD} X! = specific port number (01 - 03)
X5) = Redirection status: 0 = no redirection
1 - 3 = redirect serial port communication
from COM1, COM2, or COM3. (See “Serial
pass-through (redirect mode)” in chapter 3.)
X5# =Timeout period in tens of milliseconds
(1 - 32767) for data pass-through mode.
X2! = Parameter (#L or #D) to set either
the Length of message to receive or the
Delimiter value. # = byte count (for L) or
# = a single ASCII character expressed in
decimal form (for D). The parameter is case
sensitive. Byte count # can be from 0 to
32767, default = 0.
The ASCII decimal # can be from 0 to 00255,
default = 00000L.
W X! %2A X5) %2A X5# %2A X2! CD|
Cpn X ! •CcdX5) , X5# , X2! ]
Terminate serial pass-through
mode24
E X! *0 CD}W X! %2A 0 CD|
Cpn X !•Ccd00000,00000,00000L]
End serial pass-through.
View serial pass-through mode E X! CD}W X! CD|
X5) , X5# , X2! ]
Ethernet port configuration and use
Set current Ethernet connection
timeout period24
E
0*X6( TC}W 0 %2A X6( TC| Pti 0*X6(
]
X6( = IP timeout period specified in
10-second steps (1 - 65000, default = 30 = 300
seconds). If no data is received during the
specified period, the Ethernet connection
closes. Responses include leading zeros.
The current port timeout period applies to the currently open Telnet session only. When
you start another Telnet session, it uses the default global port timeout period.
View current connection timeout
period13 E
0TC}W 0TC| X6(
]
Set global Ethernet connection
timeout period24 E
1*X6( TC}W 1 %2A X6( TC|Pti 1*X6(
]
View global connection timeout
period E 1TC}W 1TC| X6(
]