Specifications — IPL T PC1, IPL T PC1i
AC control interface
Connectors |
|
IPL T PC1 | 1 female USA/Edison power connector |
IPL T PC1i | 1 female IEC power connector |
Voltage |
|
IPL T PC1 | 120 VAC, |
IPL T PC1i | 220 VAC, |
Maximum AC load |
|
IPL T PC1 | 12 A, 1440 watts at 120 VAC |
IPL T PC1i | 10 A, 2200 watts at 220 VAC |
Serial control interface
Serial control port | (1) |
Baud rate and protocol | 115200 to 300 baud (9600 baud = default) ; 8 (default) or 7 data bits; 1 (default) or 2 |
| stop bits; no parity (default), or even or odd parity |
Serial control pin configurations | 1 = TX, 2 = RX, 3 = GND, 4 = +5 VDC |
Ethernet control interface
Connector | 1 |
Data rate | |
Protocols | ARP, DHCP, ICMP (ping), TCP/IP, UDP/IP, Telnet, HTTP, SMTP |
Default settings | Link speed and duplex level = autodetected |
| IP address = 192.168.254.254 |
| Subnet mask = 255.255.0.0 |
| Gateway = 0.0.0.0 |
| DHCP = off |
Web server | Up to 200 simultaneous sessions |
| 7.25 MB nonvolatile user memory |
Program control | Extron’s Simple Instruction Set (SIS™) |
Global Viewer requirements | Microsoft® Internet Explorer ver. 6 or higher |
Contact closure interface (input only)
Quantity/type | 1 contact closure input |
Contact input control connector . (1) 3.5 mm captive screw connector, 4 pole (shared with IR output port) | |
Contact closure (input only) |
|
Input voltage range | 0 to 5 VDC, clamped at +5.1 V |
Input impedance | 10k ohms |
Threshold | 1.6 VDC |
Pin configuration | 1 = contact input, 2 = GND |
IR control interface
IR control port | (1) 3.5 mm captive screw connector, 4 pole (shared with contact closure input port) |
Pin configurations | 3 = S (IR signal output), 4 = GND |
IR output carrier frequency | 30 kHz to 1 MHz |
General
Power input | 100 VAC to 240 VAC, 50/60 Hz, 5 watts, internal, on 1 male IEC power connector |
IPL T PC1 | 12 A (max.) |
IPL T PC1i | 10 A (max.) |
Temperature/humidity | Storage: |
| Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing |
Cooling | Convection, unvented |