Extron electronic MATRIX 3200, MKP 1200 manual Wiring Cables from MKP 1000/1200 to MKP 1000/1200

Models: MATRIX 12800 MATRIX 6400 MKP 1200 MATRIX 3200 MKP 1000

1 1
Download 1 pages 3.42 Kb
Page 1
Image 1
Wiring Cables from MKP 1000/1200 to Matrix 12800/6400/3200

Wiring Cables from MKP 1000/1200 to Matrix 12800/6400/3200

WARNING

The two ends of the cable MUST BE WIRED THE SAME or damage to circuits will occur.

Matrix 12800/6400/3200

MKP 1000/1200

 

Wiring Cables from MKP 1000/1200 to MKP 1000/1200

WARNING

The two ends of the cable MUST BE WIRED THE SAME or damage to circuits will occur.

MKP 1000/1200

MKP 1000/1200

Red

Blue*

White

Drain

Black

Black

Drain

White

Blue*

Red

For star configuration, two or three wires can be installed in each terminal.

Black

Black

Drain

Drain

White

White

Blue*

Blue*

Red

Red

5 mm Captive

Screw Connector

3.5mm Captive Screw Connector

3.5 mm Captive

3.5 mm Captive

Screw Connector

Screw Connector

Control Cable

* Sometimes violet

Control Cable

* Sometimes violet

1230 South Lewis Street, Anaheim, CA 92805

68-355-06 Rev C

02 03

714.491.1500 Fax 714.491.1517

Printed in USA

 

Page 1
Image 1
Extron electronic MATRIX 3200, MKP 1200 manual Wiring Cables from MKP 1000/1200 to MKP 1000/1200, Matrix 12800/6400/3200