MSW 4V SDI rs • Installation and Operation
Installation and Operation, cont’d
2-8
MSW 4V SDI rs • Installation and Operation

2-9

Front Panel Controls and Indicators

Figure 2-7 shows the front panels of the MSW 4V SDI rs.
A/V SWITCHER
MODE NORMAL AUTO
AUTO
SWITCH
1234
6
2
1
5 4 3
Figure 2-7 — MSW 4V SDI rs front panel

Input selection

a Input 1 through 4 LEDs — The Input LEDs identify the selected
input.
b Input 1 through 4 buttons — Each Input button selects the
associated input for output.
The Input 1 (e), Input 2 (d), and Input 3 (c) buttons are also
used to toggle autoswitch mode on and off. See "Autoswitch
mode controls and indicators" below.

Autoswitch mode controls and indicators

c Auto(switch) button — The Auto button is used with the Mode
button (e) to select the autoswitch mode. Auto is a secondary
function of the Input 3 button.
d Normal button — The Normal button is used with the Mode
button (e) to select normal mode. Normal is a secondary
function of the Input 2 button.
e Mode button — The Mode button is used with the Normal
button (d) or Auto button (c) to select the switching mode.
Mode is a secondary function of the Input 1 button. See "Mode
selection", on the following page.
f Auto Switch LED — When lit, the Auto Switch LED indicates
that the switcher is in autoswitch mode. In this mode, the MSW
automatically switches to the highest numbered input with
active sync pulses. When this LED is unlit, the switcher is in
normal (manual) mode.

Mode selection

To turn autoswitch mode on:
1. Press and hold the Mode (Input 1) button.
2. Press and hold the Auto (Input 3) button.
3. Release the Mode and Auto buttons simultaneously.
A/V SWITCHER
MODE NORMAL AUTO
AUTO
SWITCH
1234
Figure 2-8 — Turning on autoswitch mode
The Auto Switch LED lights, indicating that autoswitch is
enabled.
To turn autoswitch mode off (Normal mode):
1. Press and hold the Mode (Input 1) button.
2. Press and hold the Normal (Input 2) button.
3. Release the Mode and Normal buttons simultaneously.
A/V SWITCHER
MODE NORMAL AUTO
AUTO
SWITCH
1234
Figure 2-9 — Turning off autoswitch mode
The Auto Switch LED is unlit and the MSW switches to the
previously selected input.
N In the event that power is disconnected from the MSW, the
unit retains mode and input settings.