Extron electronic setup guide MTP 1500RL 15HD A SEQ Setup Guide, Mounting, Connect Input

Models: MTP 1500RL 15HD A SEQ

1 2
Download 2 pages 35.65 Kb
Page 1
Image 1
MTP 1500RL 15HD A SEQ • Setup Guide

MTP 1500RL 15HD A SEQ • Setup Guide

This guide provides basic instructions for an experienced installer to set up and operate the Extron MTP 1500RL 15HD A SEQ twisted pair receiver.

For full details, see the MTP 1500RL 15HD A SEQ User Guide, available online at www.extron.com.

RED

LEVEL

PEAKING

SELECT Installation and SetupGREEN

BLUE

ADJUST

 

MIN/MAX

DELAY

RGB

MTP 1500RL Series

INPUT

BUFFERED OUTPUT

OUTPUT

 

POWER

 

MONO

AUDIO

12V

 

L

R

1.0A MAX

 

 

 

MTP

MTP

 

 

SPARE

END

VIDEO

SOG

CSYNC

V +

H +

ON

MTP 1500RL 15HD A SEQ

Installation and Setup

Step 1 — Mounting

Turn off or disconnect all equipment power sources. Mount the MTP 1500RL 15HD A SEQ receiver as required.

Step 2 — Connect Input

Connect the RJ-45 cable from an MTP transmitter to the Input port on the MTP 1500RL 15HD A SEQ receiver.

Terminate the cable as shown below right, using the same standard (A or B) at both ends.

 

 

 

 

 

 

Pin

T568A Wire

T568B Wire

 

 

 

 

 

 

 

Color

Color

RJ-45 Connector

 

 

 

 

 

 

1

White-green

White-orange

 

 

Pins:

 

 

 

12345678

 

 

2

Green

Orange

 

 

 

 

 

 

 

 

 

 

 

 

3

White-orange

White-green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Blue

Blue

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

White-blue

White-blue

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Orange

Green

 

 

 

 

Insert Twisted

7

White-brown

White-brown

 

Pair Wires

 

 

 

 

8

Brown

Brown

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: The transmitter and receiver are designed for and perform best with Extron Enhanced Skew-Free AV cable terminated in accordance with the TIA/EIA T568A standard. CAT 5 cables are acceptable but less preferable. Using preterminated and tested cables is also recommend, Cables terminated on site should be tested before use to ensure that they comply with Category 5 specifications.

Step 3 — Connect Outputs

Attach the applicable output cables (video, audio, and buffered output).

A.High resolution video output — Connect a display device to the 15-pin HD connector (RGB).

B.Audio connector — Connect an audio device to the 5-pole captive screw connector for mono audio output

 

Mono output 1

MONO 1

Mono output 1+

 

NO GROUND.

Mono output 1-

 

Sleeve(s)

AUDIO 2

Sleeve(s)

Do not tin the wires!

Mono output 2

Mono output 2+

NO GROUND.

 

Mono output 2-

Unbalanced Output
Balanced Output

CAUTION

For unbalanced audio, connect the sleeve(s) to the ground contact.

DO NOT connect the sleeves to the negative (-) contacts.

MONO AUDIO 1 2

C.Buffered output — Connect up to 5 daisy-chained MTP receivers to this RJ-45 connector.

Page 1
Image 1
Extron electronic setup guide MTP 1500RL 15HD A SEQ Setup Guide, Mounting, Connect Input, Installation and Setup