Extron electronic PPC 25 Installation Procedure, Testing and Adjustment Procedure

Models: PPC 25

1 2
Download 2 pages 61.53 Kb
Page 2
Image 2
PPC 25 Installation Instructions, cont’d

PPC 25 Installation Instructions, cont’d

Installation Procedure

Follow all local fire and safety code requirements for installation and anchoring. Install the PPC 25 Sensor in a UL-compliant junction box with a cover to meet plenum rating requirements.

1. Open the top of the Priority Page Sensor.

From

Priority

PA system

Page

 

 

Sensor

Ceiling Mounted

Paging Speaker

To Priority

Page Controller

2. Loop either one of the speaker wire leads around the top (open) part of the Sensor, and connect it to the speaker as shown above. Connect the other speaker wire directly to the speaker. Polarity need not be observed.

For a 25V or 70V system — wrap 5 to 8 loops.

For a 4/8 ohm system — wrap 2 to 4 loops.

3. Close and latch the top of the Priority Page Sensor.

4. Cut an 18" section from the unterminated end of the supplied blue sensor cable for use in step 8 below.

5. Strip 3/16” of insulation from each conductor on the bare wire end of the blue sensor cable. Do not tin the leads.

6. Connect the stripped leads to the 2-pole captive screw connector on the Priority Page Sensor. Polarity need not be observed.

Blue

Sensor

Cable

7. Route the connector end to the PPC 25 Controller, and plug it into the PAGING SENSOR receptacle.

8. Connect the 18” 2-conductor cable (from step 4) from the RELAY OUT port on the PPC 25 Controller to the mute control input port on the audio amp or switcher to be muted during a PA system announcement. Polarity need not be observed.

When integrating the PPC 25 into a PoleVault System:

1. Connect the 18” cable (from step 4 above) from the RELAY OUT port on the PPC 25 Controller to the MUTE and GROUND pins on the PoleVault PVS 204SA VOL/MUTE port. Polarity need not be observed.

2. Use the included cable assembly (PN 27-576-01LF) to power the PPC 25 from the PVS 204SA power supply. The PPC 25 must be mounted near the PVS 204SA and its power supply.

 

 

AMPLIFIED OUTPUTS

 

Extron

 

 

4/8

 

 

 

Ohms

 

PVS 204SA

RS-232 MLC/IR

 

 

 

 

L

R

Mute (center)

Rear Panel

Tx Rx IR

12V

DC VOL

 

 

 

Ground (right)

 

A B C

 

VOL/MUTE

 

 

10V

 

Extron

PPC 25

Priority Page

Controller

Testing and Adjustment Procedure

Extron

 

To test that the classroom audio is muted when a

US

PVS 204SA

 

PA system announcment (page) occurs:

Twisted Pair

 

1.

Turn the classroom audio on.

Switcher

 

 

POW

 

 

 

ER

2.

Speak into the PA system microphone. The classroom

 

 

audio should be muted while the PA system page occurs, and be restored when the page ends.

To Power Supply

3. If the PPC 25 fails to mute the classroom audio during a page, turn the SENSITIVITY adjustment clockwise.

4. If classroom audio is muted without a page occurring, turn the SENSITIVITY adjustment counterclockwise.

www.extron.com

Extron Electronics, USA 1230 South Lewis Street Anaheim, CA 92805 800.633.9876 714.491.1500 FAX 714.491.1517

Extron Electronics, Europe

Beeldschermweg 6C

3821 AH Amersfoort, The Netherlands +800.3987.6673 +31.33.453.4040 FAX +31.33.453.4050

Extron Electronics, Asia

135 Joo Seng Rd. #04-01

PM Industrial Bldg., Singapore 368363 +800.7339.8766 +65.6383.4400 FAX +65.6383.4664

Extron Electronics, Japan

Kyodo Building, 16 Ichibancho

Chiyoda-ku, Tokyo 102-0082

Japan

+81.3.3511.7655 FAX +81.3.3511.

2PPC 25 Priority Page Sensor • Installation Instructions

Page 2
Image 2
Extron electronic PPC 25 installation instructions Installation Procedure, Testing and Adjustment Procedure