Extron External Power Supply •
Installation Guide
2.Fasten the power output cord to the ZipClip base.
a.Insert tie wraps (“zip ties”) along the notches on the side of the power supply and
Important Safety Instructions
This symbol is intended to alert the user of impor- tant operating and maintenance (servicing) instruc- tions in the literature provided with the equipment.
This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product enclosure that may present a risk of electric shock. On the product, risk of shock may be indicated by this symbol.
Read these instructions. Keep these instructions. Heed all warnings.
Follow all instructions.
Do not use this apparatus near water.
Clean only with dry cloth.
Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
Do not defeat the safety purpose of the polarized or
Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
Only use attachments/accessories specified by the manufacturer.
Unplug this device apparatus during lightning storms or when unused for long periods of time.
WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
This apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases shall be placed on the apparatus.
Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as when the
WARNING: This apparatus is a Class I product. This product must be connected to a MAINS socket outlet with a protective earthing connection.
The mains plug is used as the disconnect device and shall remain readily operable.
To prevent the risk of shock, do not attempt to service this equipment yourself because opening or removing covers may expose you to dangerous voltage or other hazards.
WARNING:
Power sources • This equipment should be operated only from
the power source indicated on the product. This equipment is intended to be used with a main power system with a grounded (neutral) conductor. The third (grounding) pin is a safety feature, do not attempt to bypass or disable it.
Power disconnection • To remove power from the equipment
safely, remove all power cords from the rear of the equipment, or the desktop power module (if detachable), or from the power source receptacle (wall plug).
through the tie wrap anchor points on the ZipClip, then around the cord.
b. Connect and pull the |
| Cable |
| Strain | |
tie wraps until they | Tie Wrap | Relief |
are secure. Do not |
|
|
over tighten. |
|
|
Mounting
CAUTION: These power supplies are not suitable for use in air handling spaces or in wall cavities. The power supply is to be located within the vicinity of the Extron AV equipment in an ordinary location with IEC 1010 pollution degree 2, and secured to an equipment rack within a dedicated closet, podium, or desk.
The installation must be in accordance with the applicable provisions of National Electrical Code ANSI/NFPA 70, article 75 and Canadian Electrical Code part 1, section 16. The power supply shall not be permanently fixed to building or similar structure.
Rack Mounting
About the Extron PS 910, PS 1210, PS 1508 Power Supplies
Model Overview
Model | Power Output | Termination |
|
|
|
PS 910C | 9 watts, 9 VDC, 1 A | Captive screw |
|
|
|
PS 910P | 9 watts, 9 VDC, 1 A | DC plug |
|
|
|
PS 1210C | 12 watts, 12 VDC, 1 A | Captive screw |
PS 1210P | 12 watts, 12 VDC, 1 A | DC plug |
|
|
|
PS 1508C | 12 watts, 15 VDC, 0.8 A | Captive screw |
ZipClip™ 100 | — | — |
|
| |
|
|
|
Cabling and Features
FeaturesNotches for Securing
ACTie Wrap Power
Input
These power supplies are one eighth rack wide. Up to eight power supplies can be mounted side by side directly onto a rack shelf.
1.Align the threaded holes in the bottom of the power supply with the holes in an Extron rack
shelf and fasten the supply to the shelf with two
b
RSB 123
Rack Shelf
a
(2)
2. Bolt the rack shelf to the rack.
| Power |
LED | |
| ZipClip |
DC Power | Mounting Slot |
Output | (front and rear) |
PS 910C, PS 1210C, PS 1508C |
| PS 910P, PS 1210P | |
| Tie Wrap |
| Tip (+) |
| Smooth |
| |
|
|
| |
Power Supply |
|
|
|
Output Cord |
|
|
|
| Ridged | Captive Screw | Sleeve |
|
| Connector | |
|
|
| |
Alternative Wiring Option |
|
| |
| Smooth |
|
|
Power Supply | N/C |
|
|
Output Cord |
|
| |
|
|
| |
| Ridged |
|
|
Using the ZipClip 100
Attaching and Removing the Clip and Power Supply
To attach the power supply to the ZipClip 100 mounting clip:
1.Insert the bottom of the power supply down into the clip, starting with one end.
2.Pivot the other end down and press until the clip snaps into place.
To remove the power supply from the ZipClip: | b | |
1. | Press the tab on the ZipClip. | |
2. | Pivot the power supply and lift it out |
|
| of the ZipClip. |
|
a
Using Tie Wraps for Cable Strain Relief
1.Attach the power supply to the ZipClip mounting clip as described
1.Fasten the ZipClip 100 mounting clip to a
rack rail using two rack screws as shown in the diagram at right.
Side of Rack
2. Insert the power supply into the ZipClip as described previously and press to snap it into place.
Inside
Rack
Pole or Table Leg Mounting
1.Wrap a tie wrap around
the projector mount pole or table leg and the power supply at one of the tie wrap notches, and fasten the tie wrap together to secure the power supply to the pole or table leg.
2.Repeat step 1 at the other tie wrap notch.
ZipClip 100
Back of
Rack
Tie Wrap to Polepreviously.
See the next page for
furniture mounting instructions.
1