WMK 100 Installation Notes, cont'd
1B. To mount the WMK 100 onto a non-masonry wall:
i.At the desired site locate the wall studs and mark their locations.
NFor ideal installation secure the base plate to at least one wall stud (see figure 3). Drywall Kap toggles can be used for holes not aligned with studs.
The base plate can be installed over an existing electrical outlet. The opening fits standard sized 2.75" x 4.5" wall plates. See inset on figure 2.
WMK 100 | Mounting | Cutout for |
|
|
|
|
| Marker for |
Base Plate | Holes | Signal Cable |
|
|
| Level Pilot Hole | ||
|
| Access |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PRELIMINARY
ii.Hold and level the base plate against the wall and mark the positions of the slotted mounting holes that are on the stud lines (see figure 3, indicated by + marks). Where applicable, mark the mounting holes on the wall for drywall toggles. Set the plate aside.
iii.Drill 1.75" (4.4 cm) deep pilot holes at the marked locations.
iv.Insert the self tapping screws into the pilot holes, until a gap of 1/8" to 3/8" (3 to 9 mm) remains between the wall and the screw heads.
NIf using toggle assemblies see figure 4 for installation method.
v. Align the base plate's slotted mounting holes | + | + |
over the installed screws, then slide the plate |
| |
|
| |
down so the screws fit into the slots. |
|
|
Cutout for
Electrical
Wall Studs Outlet
Figure 3 — Non-masonry wall mounting
a. Grasp handle, collapse | b. Slide plastic washer | |||||||||
toggle and insert into wall. | down into pilot hole. | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
vi.At this time, lightly tighten all the screws to ensure plate fits flush to the wall and verify level and position.
NDo not over tighten, as the plate needs to be removed to attach the switcher and power supply before cabling.
vii.If the cables are to be run behind the wall to the WMK location, mark the cutout area on the wall for the signal cable access hole (see figure 3).
viii.Remove the base plate and cut out the marked area.
c. Cut off handle close to wall. d. Hand screw in pan head bolt until 1/8" gap remains.
Figure 4 — Toggle assembly installation
2.Mount the switcher and power supply
a.Remove the WMK 100 base plate from the wall, and with the switcher's rear ports facing the cable access hole, align
the two corner holes in the base of the switcher with the two outermost device mounting holes in the WMK 100 base plate. Secure with the supplied 440 x ¼" screws.
b.Attach the power supply above the electrical outlet cutout, with the supplied
c.
PVS305SA POLEVAULTSWITCHER | AUDIOLEVELADJUST | MIC | SENSITIVITY |
|
| INPUT |
|
| 5 |
| AUXAUDIO |
| 4 |
|
|
INPUTSELECTION | 3 |
|
|
| 2 |
|
|
| 1 |
|
|
|
|
| CONFIG |
(2)
Figure 5 — Attach switcher and power supply to base plate
2