WMK 100 Installation Notes
The Extron WMK 100 Wall Mounting Kit is used for hanging PoleVault® System A/V products on a wall near a flat screen display or short throw projector.
The WMK 100 has a 13" x 13" x 2.5" deep enclosure to mount the PoleVault switcher and the power supply, with room for cable management. It also has knockouts on all four sides which allow external raceways to be used where necessary for cabling.
CMaximum load for the WMK 100 is 15 lbs (7 kg).
The key components (base plate and cover) of the WMK 100 are shown in figure 1.
Included in the kit are:
(4)
(4)¼ x 1¾" masonry screws, (4) #14 x 1¾" self tapping metal/wood screws, (4)
Not shown but included are (3)
Installation
(4)
Pan Head Bolts
(4) 1/4" Kap Toggle Assemblies
(4) 1/4" x 1 3/4" Masonry Screws
(4)#14 x 1 3/4"
(4) 6/32" x 1/4" Button Head Hex Screws
Figure 1 — WMK 100 parts
NRefer to local building standards and codes to verify that the installation will meet the regulatory requirements. Observe all local and national building and safety codes, UL requirements, and ADA accessibility guidelines.
Before installation identify the type of wall (masonry or
PRELIMINARY
1. Mount the base plate
Follow the steps within 1A or 1B below, as applicable.
NThe base plate can be installed over an existing electrical outlet. The opening fits standard sized 2.75" x 4.5" wall plates. See figure 2 (inset).
1A. To mount the WMK 100 onto masonry walls:
i.Hold the base against the wall, level it, and mark the positions of four slotted mounting holes (indicated by + marks in figure 2). Set the plate aside.
NUse the top slot position at each mounting hole. Do not use both top and left slots as this will make it difficult to slide the plate down (see step iv).
ii.Using a masonry drill bit, drill 1.75" (4.4 cm) deep pilot holes at the marked locations.
iii.Screw in masonry screws until a gap of 1/8" to 3/8"
(3 to 9 mm) remains between the wall and the screw heads.
iv. Align the base plate's slotted mounting holes over | + | + |
the installed screws, then slide the plate down so |
| |
|
| |
the screws fit into the slots. |
|
|
v.At this time, lightly tighten all the screws to secure the plate to the wall and verify level and position.
NDo not over tighten, as the plate needs to be removed to attach the switcher and power supply before cabling.
Proceed to Step 2.
WMK 100 | Mounting | Cutout for |
|
| Marker for |
Base Plate | Holes | Signal Cable |
|
| Level Pilot Hole |
|
| Access |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Cutout for
Electrical
Outlet
The plate can be aligned over an existing electrical outlet.
Figure 2 — Masonry wall mounting
Rev A
06 09
1