Power consumption at 230 VAC, 50 Hz |
| |
Typical (1/8 power) |
|
|
XPA 2002 | 4 ohms (x2): 85.6 watts | |
| 8 ohms (x2): 54.4 watts | |
XPA | 70 V (x2): 85.6 watts | |
XPA | 100 V (x2): 90.4 watts | |
XPA | 4 ohms (x2) + 70 V: 122.4 watts | |
| 8 ohms (x2) + 70 V: 92.9 watts | |
XPA | 4 ohms (x2) + 100 V: 123.3 watts | |
| 8 ohms (x2) + 100 V: 95.3 watts | |
XPA 2004 | 4 ohms (x4): 146.2 watts | |
| 8 ohms (x4): 89.9 watts | |
Quiescent |
|
|
XPA 2002 | 10.9 watts |
|
XPA | 23.1 watts |
|
XPA | 26.2 watts |
|
XPA | 29.8 watts |
|
XPA | 28.6 watts |
|
XPA 2004 | 29.0 watts |
|
Standby | <1 watt (triggered by contact closure or after 25 minutes [±5 | |
| minutes] with no signal) | |
Temperature/humidity | Storage: | |
| noncondensing | |
| Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, | |
| noncondensing | |
Cooling | Convection, no vents, with heat sinks on the sides | |
Thermal dissipation at 115 VAC, 60 Hz |
| |
Standby | <1 watt (3 BTU/hr) | |
Idle |
|
|
XPA 2002 | 10.9 watts (37 BTU/hr) | |
XPA | 20.8 watts | (71 BTU/hr) |
XPA | 25.1 watts | (86 BTU/hr) |
XPA | 28.9 watts (99 BTU/hr) | |
XPA | 28.1 watts (96 BTU/hr) | |
XPA 2004 | 28.7 watts (98 BTU/hr) | |
1/8 power |
|
|
XPA 2002 | 4 ohms (x2): 34.7 watts (119 BTU/hr) | |
| 8 ohms (x2): 28.4 watts (97 BTU/hr) | |
XPA | 70 V (x2): 34.5 watts (118 BTU/hr) | |
XPA | 100 V (x2): 39.6 watts (135 BTU/hr) | |
XPA | 4 ohms (x2) + 70 V: 47.4 watts (162 BTU/hr) | |
| 8 ohms (x2) + 70 V: 42.2 watts (144 BTU/hr) | |
XPA | 4 ohms (x2) + 100 V: 48.1 watts (164 BTU/hr) | |
| 8 ohms (x2) + 100 V: 44.4 watts (152 BTU/hr) | |
XPA 2004 | 4 ohms (x4): 46.5 watts (159 BTU/hr) | |
| 8 ohms (x4): 39.3 watts (134 BTU/hr) | |
Thermal dissipation at 230 VAC, 50 Hz |
| |
Standby | <1 watt (3 BTU/hr) | |
Idle |
|
|
XPA 2002 | 10.9 watts (37 BTU/hr) | |
XPA | 23.1 watts (79 BTU/hr) | |
XPA | 26.2 watts (89 BTU/hr) | |
XPA | 29.8 watts (102 BTU/hr) | |
XPA | 28.6 watts (98 BTU/hr) |
XTRA Full Rack Power Amplifier Series • Reference Information | 21 |