Faber 630006500, 630006499, 630006501, 630006498 manual Dimensional Diagrams, 30” Ducted, 36” Ducted

Models: 630006498 630006500 630006501 630006499

1 2
Download 2 pages 49.91 Kb
Page 2
Image 2
Dimensional Diagrams
For installations where ductwork is impos- sible or highly impractical, a Ductless Conversion Kit is available. A charcoal filter, which attaches under the blower assembly, absorbs smoke and odors. A ductless diverter assembly directs the air out to a lower chimney with vent grates cut into the sides.
* it is highly recommended that professional style cooking always be
vented to the outside.
Rev. 06/08
Ductless Installations*

Dimensional Diagrams

30” Ducted

36” Ducted

Pre-Planning Your Installation - Important: Consult the installation instructions before you begin installing this rangehood.

Ducted

1” min 21 10/16max

22 1/16”

upper chimney

lower chimney

min & max ceiling height examples

x = 24"

x = 26"

x = 28"

x = 30"

7'

min

7'

min

8'

min

 

min

9 2/16"

11 2/16"

1 2/16"

8'

3 2/16

max

9'

max

max

9'

max

9'

5 2/16"

7 2/16"

9'

9 2/16"

11 2/16"

For ducted installations the chimneys are adjustable and designed to meet varying ceiling heights between 7’ 9 2/16” and 9’ 11 2/16” depending on the distance between the bottom of the hood and the cooktop (distance x in the ducted diagram).

9 7/16”

 

canopy

 

 

 

 

 

 

 

 

 

 

19

 

x

x=distancefromhoodtocooktop

(varies depending on installation)

 

min - 24”, suggested max - 30”

 

 

also consult cooktop

 

manufacturer's recommendation

36”

cabinet base

 

For shorter ceilings, have the chimney cover(s) cut at a sheet metal shop. For higher ceiling installations, the High Ceiling Chimney Kit includes a new 39” upper chimney which would replace the 21 10/16” upper chimney that came with the hood.

Note: If 24” or 30” High Backsplash is being installed, the distance between the bottom of the hood and the cooktop (distance x in diagram) is equal to the height of the Backsplash.

Pre-Planning Your Installation - Important: Consult the installation instructions before you begin installing this rangehood.

Make your ductrun as straight and short as possible. The ductrun should not exceed 35 equivalent feet if ducted with the required minimum of 6” round duct. Count 45º angles as 3 feet, 90º elbows as 5 feet, and 90º flat elbows as 12 feet.

For best results, use no more than three 90° elbows. Make sure that there is a minimum of 24” of straight duct between elbows if more than one is used. Do not install two elbows together. If you must elbow right away, do it as far away from the hood’s exhaust opening as possible.

WARNING! Product specifications are subject to change without notification. Consult the installation instructions before you begin installing this rangehood.

Page 2
Image 2
Faber 630006500, 630006499, 630006501, 630006498 manual Dimensional Diagrams, 30” Ducted, 36” Ducted