GETTING TO KNOW YOUR FANTOM HAND HELD
OPERATING INSTRUCTIONS cont.
STEAM CLEANER
1. | Safety Cap | 11. | Trigger Lock |
2. | Shoulder Strap Hook | 12. | Nylon Detail Brush (x2) |
3. | Shoulder Strap Loop | 13. | Angle Concentrator/Brush Adapter |
4. | Main Unit | 14. | Extension Tubes (x2) |
5. | Handle | 15. | Window Squeegee |
6. | Power Cord | 16. | Floor Brush |
7. | Indicator Light | 17. | Filling Flask |
8. | Flexible Hose | 18. | Shoulder Strap |
9. | Hand Grip | 19. | Angle Adapter (Floor Brush) |
10. | Steam Trigger |
|
|
Technical Specifications |
|
Voltage: | 120V., 60Hz. |
Power: | 1600 Watts |
Water Capacity: | 28 U.S. Fl. Oz.(800ml) |
Care & Maintenance
CAUTION: This appliance must be unplugged from the electrical outlet and allowed to cool down before performing any cleaning or maintenance tasks on the unit.
•Let the appliance cool down completely before cleaning or storing.
•Depress the trigger before opening the safety cap in order to release any residual pressure in the boiler.
•Empty all water from the water tank after each use.
•Store in a dry, cool place.
•A periodic rinse of your steam cleaner will free it from deposits. This is recommended every
Cleaning the Angle Concentrator:
Your steamer should not normally require cleaning, however, should you notice a marked decrease in steam output it may be necessary to remove mineral deposit build- up from the angle concentrator orifice. First ensure that there is water in the tank. If tank is empty, fill with water, (we recommend using purified or demineralized water), then
1.Unplug steam cleaner from wall outlet.
2.Use a small diameter stiff metal wire such as a straightened metal paperclip and carefully insert the end of the wire into the angle concentrator orifice.
3.Move wire back and forth several times to remove any deposits.
4.Reconnect appliance to power outlet, switch on and note steam output.
5.If steam performance does not improve, repeat steps #1 through #4.
Attaching the Shoulder Strap
Using the detachable shoulder strap allows for greater freedom of movement when both hands are needed for various cleaning tasks. To attach the shoulder strap to the steam cleaner, simply snap the shoulder strap hooks onto the connecting rings on the unit body. When using the steam cleaner with the shoulder strap, avoid rocking or tilting the unit excessively as this may cause water to enter the hose and be discharged along with the steam.
Connecting Points
Note: Illustrations may differ from actual unit.
Paper clip
3 | 8 |