Installation Manual

Models ECCB/TCCB 30” – 36” ENGLISH

Electrical Connections

DANGER

Disconnect power before servicing the product. Failure to do so could result in death or electrical shock.

General information

This cooktop does not require a neutral connection. If the cooktop is to be completely enclosed in a cabinet, feed the cooktop cable through the opening in the cabinet. Make the electrical connection following the appropriate steps for your installation.

Your cooktop must be connected to the proper electrical voltage and frequency as specified in the table on the right.

Figure 13. Location of serial tag

Connect with copper wire only

If the house has aluminum wiring, follow the procedure below:

1.Connect the aluminum wiring to the copper wire by using special connectors designed and Underwriters Laboratories-listed for joining copper to aluminum. Follow the electrical connector manufacturer's recommended procedure.

2.Aluminum/copper connection must conform with local codes and industry- accepted wiring practices.

The flexible conduit (supplied) 3 feet long (100 cm) located at the right rear of the cooktop bottom box should be connected directly to junction box. Do not cut the conduit. A U.L - or CSA - listed conduit connector must be provided at each end of the power

supply cable (at the cooktop and at the junction box.) A time delay fuse or circuit breaker is recommended. Do not ground to a gas pipe. Do not have a fuse in the grounding or neutral circuit.

Fuse both supply (phase) lines.

WARNING

Improper connection of aluminum house wiring to the copper leads can result in a serious problem.

 

 

 

Required

Minimum

 

Model

Power

power

supply wire

 

 

 

supply

size

 

TCCB 33052/**

 

 

 

 

TCCB 33053/**

 

 

 

 

TCCB 33066/**

 

 

 

30”

TCCB 33067/**

6.7 kW

240 V 28 A

No.

ECCB 33050/**

60 Hz

10AWG

 

ECCB 33051/**

 

 

 

 

ECCB 33070/**

 

 

 

 

ECCB 33071/**

 

 

 

 

TCCB 33656/**

 

 

 

 

TCCB 33657/**

7.6 kW

240 V 32 A

No.

 

TCCB 33668/**

60 Hz

10AWG

36”

TCCB 33669/**

 

 

 

ECCB 33654/**

 

 

 

 

 

 

 

 

ECCB 33655/**

9.4 kW

240 V 39 A

No.

 

ECCB 33674/**

60 Hz

10AWG

 

ECCB 33675/**

 

 

 

*Digits identifying color cooktop

National Fire Protection Association

Batter/march Park Quincy, Massachusetts 02269

A three-wire, single phase, 240 volt 60 cycle electrical system (properly circuit protected to meet Local Codes of NFPA No.70) must be provided. Unit must be properly grounded in accordance with local wiring code. The chart below recommends the minimum circuit protector and wire size if the appliance is the only unit on the circuit. If smaller sizes of wire are used, the unit efficiency will be reduced and a fire hazard may be created. It is advisable that the electrical wiring and hookup be accomplished by a competent electrician.

12

Page 12
Image 12