Fedders C10 Cooling Performance Data Matching Air Handler, Model Specifications, Model Number

Models: C10

1 4
Download 4 pages 5.67 Kb
Page 3
Image 3
REFRIGERANT LINE CONNECTIONS

MODEL SPECIFICATIONS

MODEL NUMBER

 

C1042BBD1VF

C1048BBD1VF

 

C1048BBD3VF

C1048BBD4VF

C1060CBD1VF

C1060CBD3VF

C1060CBD4VF

PERFORMANCE DATA

 

 

 

 

 

 

 

 

 

NOMINAL COOLING BTU/H

 

40 000

 

45 000

 

 

56 000

 

SEER BTU/H-W

 

10.0

 

10.0

 

 

10.0

 

CFM

 

1300

 

1600

 

 

1750

 

VOLTS/HZ/PHASE

 

208-230/60/1

208-230/60/1

 

208-230/60/3

460/60/3

208-230/60/1

208-230/60/3

460/60/3

VOLTAGE RANGE

 

197-253

197-253

 

187-253

415-508

197-253

187-253

415-508

OPERATING CURRENT AMPS

20.7

26.7

 

16.6

8.7

29.2

18.8

9.1

MIN. WIRE AMPACITY

 

26.4

31.8

 

19.3

11.0

36.0

23.0

12.0

MAX. HACR BREAKER

35

50

 

30

15

60

35

15

COMPRESSOR DATA

 

 

 

 

 

 

 

 

 

RLA

 

18.5

24.5

 

14.8

7.5

27.0

16.6

7.9

LRA

 

103

137

 

91

46

150

124

59

FAN DATA

 

 

 

 

 

 

 

 

 

DIAMETER

 

18 INCH / 4 BLADE

 

 

18 INCH / 4 BLADE

 

 

22 INCH / 3 BLADE

 

MOTOR TYPE

 

PSC

 

 

PSC

 

 

PSC

 

HP (W) / FLA

 

1/5 / 1.8

1/5

/ 1.8

1/4 / 1.2

1/4

/ 2.2

1/4 / 1.2

RPM

 

1075

 

1075

 

 

1075

 

CFM

 

2400

 

2400

 

 

3 400

 

OUTDOOR COIL

 

 

 

 

 

 

 

 

 

TYPE

 

ENHANCED ALUMINUM PLATE FIN / RIFLED COPPER TUBE

 

 

FACE AREA

 

12.0

 

12.0

 

 

18.3

 

O.D. / F.P.I.-ROWS

 

3/8 / 18-1

 

3/8 / 22-1

 

 

3/8 / 18-1

 

REFRIGERANT LINE CONNECTIONS

(SERVICE PORT I.D.)

 

 

 

 

 

 

LIQUID

 

3/8 ID

 

 

3/8 ID

 

 

3/8 ID

 

VAPOR

 

3/4 ID

 

 

7/8 ID

 

 

7/8 ID

 

WEIGHTS

 

 

 

 

 

 

 

 

 

NET WEIGHT — lbs.

 

148

 

150

 

 

201

 

SHIPPING WEIGHT — lbs.

 

156

 

158

 

 

210

 

 

 

 

 

 

 

 

 

 

 

COOLING PERFORMANCE DATA MATCHING AIR HANDLER

OUTDOOR

AIR

RATINGS AT STANDARD CONDITIONS

 

COOLING DATA AT EXTENDED OUTDOOR AMBIENTS °F.M.B.T.U.H.

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT

HANDLER

BTUH

 

CFM

 

80

85

90

95

100

105

110

115

MODEL*

SEER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C1018BBD1

A24B1

18 000

10

600

TOTAL

20 200

19 700

19 100

18 000

17 600

16 800

15 900

15 000

SENSIBLE

14 500

14 100

13 700

12 900

12 700

12 150

11 500

10 900

 

 

 

 

 

C1024BBD1

A24B1

22 400

10

800

TOTAL

25 500

24 700

23 800

22 400

22 200

21 500

20 700

19 900

SENSIBLE

18 150

17 600

17 150

16 700

16 000

15 550

15 000

14 350

 

 

 

 

 

C1030BBD1

A36B1

28 600

10

1000

TOTAL

31 300

30 500

29 800

28 600

28 000

27 000

26 000

25 000

SENSIBLE

21 900

22 700

22 150

21 450

21 100

20 400

19 650

18 750

 

 

 

 

 

C1036BBD1

A36B1

34 000

10

1200

TOTAL

36 400

36 000

35 500

34 000

32 400

30 700

29 100

27 500

SENSIBLE

26 300

25 900

26 450

25 600

24 450

23 250

22 100

20 650

 

 

 

 

 

C1042BBD1

A42B1

40 000

10

1300

TOTAL

43 000

42 000

41 000

40 000

38 500

37 000

35 500

34 000

SENSIBLE

31 400

30 850

30 000

29 400

28 000

26 900

25 600

24 550

 

 

 

 

 

C1048BBD1

A48B2

45 000

10

1600

TOTAL

49 700

48 500

47 300

46 000

44 400

43 000

41 500

39 800

SENSIBLE

34 950

57 900

33 600

32 400

31 850

31 100

30 700

29 000

 

 

 

 

 

C1060CBD1

A60B1

56 000

10

1750

TOTAL

58 800

57 900

56 900

56 000

54 000

52 000

50 000

48 000

SENSIBLE

41 400

41 000

40 550

40 300

39 000

37 600

36 400

35 050

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Residential & Light Commercial – 10 SEER Remote Condensing Units

Page 3
Image 3
Fedders C10 Cooling Performance Data Matching Air Handler, Model Specifications, Model Number, Compressor Data, Fan Data